Fluke PM 3380B Autoranging CombiScope, 100 MHz, 2-Channel

Fluke Digital Oscilloscopes. Voltage: 300 V CAT II, Accuracy: ± 1% of full scale.

Model
Fluke PM 3380B
Calibration
Available on request
Price
$830
Status
In stock
RFQ ref
PM 3380B
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Fluke PM 3380B is a 100 MHz, 2-channel CombiScope that integrates analog and digital storage oscilloscope functionality in a single instrument. Engineered for precision electronics testing and troubleshooting, it delivers dual-mode operation - switching between analog and digital displays to suit different signal conditions and analysis requirements. The instrument combines a bright display, advanced triggering architecture, and versatile measurement capabilities to support detailed waveform characterization and fault isolation.


Technical Specifications

Bandwidth & Sampling

  • 100 MHz bandwidth

  • Real-time sampling: 200 MS/s (single channel), 100 MS/s (dual channel)

  • Equivalent-time sampling: Up to 10 GS/s on repetitive signals

  • Peak-detect mode captures transients as narrow as 5 ns Vertical System

  • 2 analog input channels; 1 MΩ ± 1% || 15 pF ± 3 pF input impedance

  • Vertical range: 2 mV/div to 5 V/div (1-2-5 sequence, full bandwidth)

  • Calibrated vernier: 2 mV/div to 12.5 V/div

  • Maximum input voltage: 300 V CAT II

  • 8-bit ADC resolution; 16-bit memory resolution

  • Accuracy (x1 magnification): ± 1% of full scale within central 8 horizontal and 6 vertical divisions Horizontal System & Memory

  • Main timebase: 0.5 s/div to 50 ns/div (1-2-5 sequence)

  • Delayed timebase: 0.5 ms/div to 50 ns/div

  • Fastest sweep speed (x10 magnification): 5 ns/div

  • Continuously variable timebase: 1 µs/div to 500 ms/div in 1 µs increments

  • Roll mode: 200 s/div to 50 ms/div

  • Acquisition memory: 8K samples per trace, expandable to 32K

  • Trace storage: 40 waveforms standard; up to 204 traces (512 samples each) with optional expansion Triggering

  • Trigger modes: Auto free run, Triggered, Single

  • Trigger types: Edge, TV (including HDTV and TV line selection), Pattern, State, Glitch (2 ns)

  • Trigger sources: CH1, CH2, External, Line

  • Trigger coupling: DC, AC (<10 Hz), LF-reject (30 kHz), HF-reject (30 kHz)

  • Trigger level: ± 8 div or automatic within signal peak-peak amplitude

  • Event delay, pre-triggering, and post-triggering capabilities Measurements & Display

  • Automated voltmeter and time measurement functions

  • Cursor measurements: Horizontal, Vertical, Both

  • Vertical readout: dV, V1 to ground, V2 to ground, Ratio

  • Horizontal readout: dT, 1/dT (Hz), Ratio, Phase

  • Cursor measurement accuracy: ± 1% of full scale

  • Probe-operated "Touch Hold and Measure" function displays VDC, VRMS, Vpk-pk, and frequency


Key Features



  • Dual-mode operation switches between analog and digital storage displays

  • Bright display for extended observation sessions

  • Peak-detect mode isolates narrow transient events

  • Segmented memory for acquisition and reference storage

  • Flexible trigger coupling rejects interference across multiple frequency bands


Typical Applications



  • Electronics design verification and signal characterization

  • Power supply and switching circuit analysis

  • Video signal troubleshooting (HDTV and standard TV line triggering)

  • Transient and glitch detection

  • Repetitive waveform analysis and comparison


Compatibility & Integration External trigger input allows synchronization with external signal sources. Standard and optional memory configurations support various trace storage requirements for post-acquisition analysis and documentation.

Specifications

ParameterValue
Frequency Range100 MHz | Voltage / Current Range: 2 mV/div to 5 V/div
Maximum input voltage300 V CAT II

Fluke PM 3380B — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Fluke PM 3380B. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Fluke PM 3380B price

This Fluke PM 3380B is listed at $830. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Fluke PM 3380B calibration cost

NIST-traceable calibration for the Fluke PM 3380B is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →