HP / Agilent 5501B Laser Head

HP / Agilent Optical Light Sources. Wavelength: 632.991 nm (vacuum wavelength: 632.991372 nm), Accuracy: ±0.1 ppm (3 sigma, Voltage: +15 V ±0.3 V at 0.79 A max.

Model
HP / Agilent 5501B
Calibration
Available on request
Price
$2,086
Status
In stock
RFQ ref
5501B
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The HP/Agilent 5501B is a two-frequency helium-neon laser head engineered for high-precision metrology and interferometry systems. This continuous-wave (CW) source delivers 180 µW to 1 mW of optical power at 632.991 nm with exceptional wavelength stability and accuracy. The 5501B automatically maintains frequency lock for reliable performance in demanding measurement applications requiring sub-ppm stability over extended operational lifetimes.


Technical Specifications

Optical Output

  • Wavelength: 632.991 nm (vacuum wavelength: 632.991372 nm)

  • Beam power: 180 µW (minimum) to 1 mW (maximum)

  • Beam diameter: 6 mm typical

  • Wavelength accuracy: ±0.1 ppm (3 sigma, lifetime)

  • Wavelength stability: ±0.002 ppm (1 hour typical); ±0.02 ppm (lifetime typical)

  • Reference frequency: 1.55 MHz to 2.4 MHz (varies by unit configuration) Electrical Requirements

  • Supply voltage: +15 V ±0.3 V at 0.79 A max; −15 V ±0.3 V at 0.67 A max

  • Operating power: 23 W

  • Warmup power: 35 W

  • Laser tube anode: 1.2 kV to 12 kV DC Physical & Environmental

  • Weight: 3.4 kg (7.5 lb)

  • Warmup time: <10 minutes (5 minutes typical)

  • Magnetic field (non-operating): <5.25 milligauss at 4.6 m distance

  • Cabling clearance: 10.16 cm (4 in) recommended


Key Features



  • Class II laser product (21 CFR 1040.10/1040.11 compliant)

  • Two-frequency CW output for interferometric applications

  • Automatic frequency stabilization

  • Sub-0.002 ppm short-term stability

  • Safety Class I electrical design with protective earth terminal


Typical Applications



  • Laser interferometry and displacement measurement

  • Precision positioning and calibration systems

  • Advanced metrology instrumentation

  • Applications demanding ppm-level wavelength accuracy


Compatibility & Integration The 5501B integrates into systems requiring dual-frequency laser sources with stable, locked optical output. Dual ±15 V supplies and thermal stabilization circuits are required. High voltage hazard present; service restricted to trained personnel.

Specifications

ParameterValue
Frequency Range1.55 MHz to 2.4 MHz (reference frequency range) | Voltage / Current Range: '+15 V ±0.3 V @ 0.79 A max
−15 V ±0.3 V @ 0.67 A max | Wavelength Range632.991 nm

HP / Agilent 5501B — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the HP / Agilent 5501B. Calibration covers output power at specified wavelengths, wavelength accuracy, 15-minute output stability, and modulation frequency accuracy where applicable. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common HP / Agilent 5501B faults: laser diode end-of-life (output below spec), fiber output connector damage, output instability. Common repairs include laser diode replacement when output falls below spec, fiber output connector repair, and thermal management service.

HP / Agilent 5501B price

This HP / Agilent 5501B is listed at $2,086. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

HP / Agilent 5501B calibration cost

NIST-traceable calibration for the HP / Agilent 5501B is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output power at specified wavelengths, wavelength accuracy, 15-minute output stability, and modulation frequency accuracy where applicable. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents