Fluke 5540A Multi-Product Calibrator
The Fluke 5540A Multi-Product Calibrator is a versatile calibration solution for a wide range of electrical test tools. It delivers precision and reliability, making it ideal for calibration labs and service centers. This calibrator offers high accuracy and broad workload coverage, ensuring consistent performance of various test instruments.
- Model
- Fluke 5540A
- Calibration
- Available on request
- Price
- $31,439
- Status
- In stock
- RFQ ref
- 5540A
This unit
The Fluke 5540A Multi-Product Calibrator delivers comprehensive calibration across digital multimeters, oscilloscopes, clamp meters, and general electrical parameters. Built to enhance calibration throughput and reduce cost of ownership, this instrument features 30 A continuous current output - eliminating duty-cycle delays - with expandable capabilities to 360 A direct or 6000 A via external amplification. It supports 4.5-digit DMM calibration at 4:1 TUR and oscilloscope bandwidth to 600 MHz, making it ideal for on-site and mobile calibration environments.
Technical Specifications
Voltage & Current Output- DC voltage: 0 V to ±1020 V
- DC current: 0 to ±30.2 A continuous
- AC voltage: 1 mV to 1020 V, 3 Hz to 500 kHz
- AC current: 10 μA to 30.2 A, 3 Hz to 30 kHz
- Volt/Hertz: 1000 V at 10 kHz / 330 V at 100 kHz Resistance, Capacitance & Inductance
- Resistance: 0 Ω to 1200 MΩ
- Capacitance: 200 pF to 120 mF
- Inductance: 12 μH to 12 H Waveforms & Temperature
- Output waveforms: Sine, triangle, truncated sine
- Dual output phantom load power: 30.9 kW
- Thermocouple types: B, C, E, J, K, L, N, R, S, U, BP, XK (10 μV/°C)
- RTD support: Pt100 (385, 395, 3916), Pt200 (385), Pt500 (385)
Key Features
- 30 A continuous current eliminates wait times during high-demand calibration cycles
- Current expansion to 360 A direct output; 6000 A with Fluke 52120A amplifier and current coils for Rogowski coil calibration
- Oscilloscope calibration to 600 MHz bandwidth covering amplitude, edges, time markers, impedance, and overload parameters
- Enhanced range design for 4.5-digit handheld DMM calibration confidence
- Expanded thermocouple and RTD coverage with improved connector interface
Typical Applications
- Handheld digital multimeter calibration
- Oscilloscope verification and adjustment
- Clamp meter and ammeter calibration up to 1500 A
- Temperature sensor (thermocouple and RTD) calibration
- AC/DC voltage, current, and impedance measurements
Compatibility & Integration The 5540A scales with the Fluke 52120A amplifier for extended current applications and supports standard thermocouple and RTD connectors for field deployment.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 3 Hz to 500 kHz (AC voltage) |
| 600 MHz oscilloscope bandwidth | Voltage / Current Range | 0 to ±30.2 A continuous (expandable to 360 A direct / 6000 A with amplifier), 0 V to ±1020 V |
Fluke 5540A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Fluke 5540A. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Fluke 5540A price
This Fluke 5540A is listed at $31,439. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Fluke 5540A calibration cost
NIST-traceable calibration for the Fluke 5540A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →