HP / Agilent 6628A DC Power Supply, 16V/200mA, 50V/1A
The HP/Agilent 6628A is a dual output DC power supply providing 16V/200mA and 50V/1A. It is a reliable source for testing and development applications requiring precise voltage and current control.
- Model
- HP / Agilent 6628A
- Calibration
- Available on request
- Price
- $790
- Status
- In stock
- RFQ ref
- 6628A
This unit
The HP/Agilent 6628A is a 50 W dual-output precision DC power supply engineered for R&D and automated test environments demanding fast programming, high accuracy, and reliable DUT protection. Each isolated output delivers independent voltage and current control with configurable series or parallel operation for application flexibility.
Technical Specifications Output Ratings
Output 1 (Low Range): 0–16 V, 0–200 mA
Output 2 (High Range): 0–50 V, 0–1 A (or alternatively 0–16 V, 0–2 A)
Both outputs rated at 50 W per output Programming & Readback Accuracy (at 25°C ±5°C)
Voltage (Low Range): ±(0.016% of setting + 3 mV) programming; ±(0.016% of setting + 3.5 mV) readback
Voltage (High Range): ±(0.016% of setting + 10 mV) programming and readback
Current (Low Range): ±(0.04% of setting + 185 µA) programming; ±(0.04% of setting + 250 µA) readback
Current (High Range): ±(0.04% of setting + 500 µA) programming; ±(0.04% of setting + 550 µA) readback Output Ripple & Noise (20 Hz to 20 MHz)
Constant Voltage: 500 µV RMS, 3 mV peak-to-peak
Constant Current: 0.1 mA RMS Input Power
Maximum: 550 W, 720 VA
Available line options: 87–106 VAC, 104–127 VAC, 191–233 VAC, or 209–250 VAC (47–66 Hz) Environmental
Operating Temperature: 0°C to 55°C
Humidity: Up to 95% relative humidity
Altitude: Up to 2000 m
Key Features
Dual isolated outputs; series or parallel connection capability
Fast up/down programming with active down-programmer sinking full rated current
Fast CV/CC crossover for transient protection
Precision low-current measurement capability
Remote sensing support
3U high form factor
Compatibility & Integration
GPIB interface (SH1, AH1, T6, L4, SR1, RL1, PP1, DC1, DT0, C0, E1)
SCPI command compatible
VXIPlug&Play drivers available
Front-panel keypad or remote control via GPIB
UL 1244 listed; IEC 61010-1 compliant
Specifications
| Parameter | Value |
|---|---|
| Voltage / Current Range | 0–1 A (or 0–16 V, 0–2 A), 0–200 mA, Input: 87–106 VAC / 104–127 VAC / 191–233 VAC / 209–250 VAC, Output 1: 0–16 V, Output 2: 0–50 V |
HP / Agilent 6628A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the HP / Agilent 6628A. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
HP / Agilent 6628A price
This HP / Agilent 6628A is listed at $790. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
HP / Agilent 6628A calibration cost
NIST-traceable calibration for the HP / Agilent 6628A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →