HP / Agilent 6812C Performance AC Power Source, 750 VA, 300 V, 6.5 A
HP / Agilent Programmable AC Power Source. Voltage: ** 0–300 Vrms, Current: ** 6.5 A RMS, Resolution: ** 16-bit.
- Model
- HP / Agilent 6812C
- Calibration
- Available on request
- Price
- $3,058
- Status
- In stock
- RFQ ref
- 6812C
This unit
The HP/Agilent 6812C is a single-phase AC power source and integrated power analyzer delivering 750 VA maximum output. It generates stable, programmable AC waveforms from DC to 1 kHz, with output voltage to 300 Vrms and peak current to 40 A. The instrument combines arbitrary waveform generation, harmonic synthesis, and transient simulation with real-time power measurement - eliminating the need for separate test equipment. A built-in 16-bit power analyzer measures voltage, current, power (real, apparent, reactive), harmonics to the 50th order, THD, and triggered waveform capture. Store up to twelve user-defined waveforms in non-volatile memory. Optional second power analyzer enables dual-node efficiency testing.
Technical Specifications
Output Power: 750 VA AC; 575 W DC
AC Voltage: 0–300 Vrms
AC Current: 6.5 A RMS, 40 A peak
DC Output: ±425 V, 5 A RMS
Frequency: DC; 45 Hz to 1 kHz
Line Regulation: 0.1%; Load Regulation: 0.5%
THD: ≤0.25% at 50/60 Hz (1% worst case, 45 Hz–1 kHz)
Voltage Ripple: −60 dB
Measurement Resolution: 16-bit
Harmonic Analysis: Amplitude and phase, DC to 50th harmonic
Key Features
Arbitrary waveform generator with user-defined and stored waveforms
Harmonic and transient disturbance simulation
DC offset capability overlaid on AC output
Integrated power analyzer: RMS, peak, real/apparent/reactive power, THD, harmonics
Overcurrent, overvoltage, overpower, and overtemperature protection
Output disconnect relays and remote TTL inhibit
LAN/LXI Core, USB, and GPIB interfaces
Typical Applications
Power supply and converter compliance testing under normal and distorted line conditions
Harmonic injection and transient response validation
Input/output efficiency measurement (with optional dual analyzer)
Device behavior characterization across frequency and waveform variants
Compatibility & Integration Standard connectivity: LAN/LXI Core, USB, GPIB. Optional RS-232 support. Single-phase output rated for 104–127 VAC input.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | DC |
| 45 Hz to 1 kHz | Voltage / Current Range | 0–300 Vrms AC (6.5 A RMS, 40 A peak) |
HP / Agilent 6812C — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the HP / Agilent 6812C. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
HP / Agilent 6812C price
This HP / Agilent 6812C is listed at $3,058. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
HP / Agilent 6812C calibration cost
NIST-traceable calibration for the HP / Agilent 6812C is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →