Agilent/Keysight 85901A

Agilent / Keysight Programmable AC Power Source. Frequency Range: 60 Hz ±0.1%, Voltage / Current Range: 115 Vrms / 230 Vrms output; 10.8–14.5 Vdc input; 90–250 Vac charger input; 12 Vdc @ 17 Ah battery.

Model
Agilent / Keysight 85901A
Calibration
Available on request
Price
$515
Status
In stock
RFQ ref
85901A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Agilent/Keysight 85901A is a portable AC power inverter that delivers 200 Watts continuous output for field and mobile test applications. It supplies selectable 115 Vrms or 230 Vrms at 60 Hz ±0.1% (crystal referenced), with rectangular waveform output specified at 135 or 270 peak ±5%. The unit integrates a sealed lead acid battery (12 Vdc, 17 Ah nominal) providing up to 2 hours of operation at 100-watt continuous load, or operates from an external 12 Vdc source for extended runtime.


A built-in charger accepts 90 to 250 Vac input (auto-selected) and fully recharges the battery in six hours or less. Complete electrical protection includes over-voltage, short-circuit, and over-load safeguards on the inverter output.


Technical Specifications



  • Output Power: 200 W continuous

  • Output Voltage: 115 Vrms or 230 Vrms (selectable)

  • Output Waveform: Rectangular, 25% dead zone; 135 or 270 V peak ±5%

  • Output Frequency: 60 Hz ±0.1% (crystal referenced)

  • External DC Input: 10.8 to 14.5 Vdc (inverter operation)

  • Charger Input: 90 to 250 Vac (auto-selected)

  • Battery: Sealed lead acid, 12 Vdc, 17 Ah nominal

  • Battery Cyclic Life: >200 cycles

  • Recharge Time: ≤6 hours from full discharge

  • Internal Battery Runtime: Up to 2 hours at 100 W continuous load

  • Battery Shelf Life: 18 months at <20 °C; 12 months at 20–30 °C; 6 months at 30–40 °C

  • Charger Power Consumption: 122 VA maximum

  • Operating Temperature: 0° to 55° C

  • Storage Temperature (with battery): -20° to 40° C

  • Storage Temperature (without battery): -40° to 70° C

  • EMI Conformance: VDE0871 level B (conducted and radiated)


Key Features



  • Over-voltage, short-circuit, and over-load protection

  • Dual-mode operation: internal battery or external 12 Vdc source

  • Portable form factor with integrated carrying handle and adjustable tilt-stand

  • Dimensions: 337 mm (W) × 125 mm (H) × 461 mm (D)

  • Weight: 14.2 kg with battery; 8.0 kg without battery


Typical Applications Spectrum analyzers (8590A, 8590E Series, 8592A, 8562A), oscilloscopes, voltmeters, and data acquisition test sets.


Compatibility & Integration External 12 Vdc battery connection terminals for extended field operation independent of internal battery status.

Specifications

ParameterValue
Frequency Range47 Hz to 66 Hz | Voltage / Current Range: 115 Vrms or 230 Vrms output

Agilent / Keysight 85901A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight 85901A. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Agilent / Keysight 85901A price

This Agilent / Keysight 85901A is listed at $515. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Agilent / Keysight 85901A calibration cost

NIST-traceable calibration for the Agilent / Keysight 85901A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →