Anritsu 69095A Synthesized CW Generator, 0.5 – 65 GHz

Anritsu 69095A,"Generates stable CW signals from 0.5 to 65 GHz. Designed for microwave testing and component validation in research and production labs."

Model
Anritsu 69095A
Calibration
Available on request
Price
$34,570
Status
In stock
RFQ ref
69095A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Anritsu 69095A is a synthesized CW generator delivering stable, continuous wave signals across 0.5 GHz to 65 GHz. Built for demanding microwave testing, component validation, and R&D/production measurements, this instrument combines synthesized architecture with high accuracy and signal integrity for applications requiring stringent phase noise and spurious performance.


Technical Specifications

Frequency Performance

  • Frequency range: 0.5 GHz to 65 GHz

  • Standard frequency resolution: 1 kHz

  • Optional resolution (Option 11): 0.1 Hz

  • Frequency switching time (typical): < 40 ms to within 1 kHz of final frequency

  • Step sweep switching: < 15 ms + 1 ms/GHz step size, or < 40 ms maximum Signal Quality

  • Phase noise: Typical –100 dBc/Hz at 10 kHz offset from 10 GHz carrier

  • Harmonic and harmonic-related spurious (500 MHz to 2.2 GHz): < –50 dBc

  • Harmonic and harmonic-related spurious (10 MHz to 50 MHz): < –30 dBc

  • Harmonic and harmonic-related spurious (50 MHz to 2 GHz): < –40 dBc Time Base & References

  • Time base aging: < 2 × 10⁻⁸/day

  • Time base aging with Option 16: < 5 × 10⁻¹⁰/day

  • Temperature coefficient: < 2 × 10⁻⁸/°C (0°C to 55°C)

  • Temperature coefficient with Option 16: < 2 × 10⁻¹⁰/°C

  • External 10 MHz reference input supported

  • 10 MHz reference output: 0.5 V p-p into 50 Ω, AC coupled


Key Features



  • IEEE 488 GPIB remote control

  • Front panel operation

  • Internal AM, FM, ΦM, and pulse modulation

  • Coaxial output connector


Typical Applications Component validation, microwave system characterization, receiver testing, and production acceptance testing across extended frequency ranges.


Compatibility & Integration Full IEEE 488 GPIB control enables integration into automated test systems and laboratory environments requiring precise frequency and power control.

Specifications

ParameterValue
Frequency Range0.5 GHz to 65 GHz | Voltage / Current Range: 0.5 V p-p into 50 Ω

Anritsu 69095A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Anritsu 69095A. Calibration covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Anritsu 69095A faults: YIG oscillator failure (no output or loss of lock), step attenuator wear (output drops or steps at set attenuation), ALC loop failure (uncontrolled output power), I/Q modulator assembly failure. HP/Agilent 836xx series most common faults are YIG oscillator failure and step attenuator contact wear causing output steps or drops at specific attenuation settings. Keysight E4428C/E4438C units most commonly develop ALC loop failure and I/Q modulator assembly faults. YIG oscillator replacement and attenuator service are stocked repairs.

Anritsu 69095A price

This Anritsu 69095A is listed at $34,570. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Anritsu 69095A calibration cost

NIST-traceable calibration for the Anritsu 69095A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents