Fluke 725 Multifunction Process Calibrator

Fluke Multifunction Calibrators. Accuracy: 0.15 Ω (15.0–400.0 Ω at 0.15–0.5 mA excitati, Accuracy: 0.2°C cold junction uncertainty, Accuracy: 0.1°C to 0.33°C depending on type.

Model
Fluke 725
Calibration
Available on request
Price
$4,160
Status
In stock
RFQ ref
725
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Fluke 725 Multifunction Process Calibrator is a portable field instrument that measures and sources electrical and physical parameters for process instrumentation calibration, maintenance, and troubleshooting. Its split-screen display enables simultaneous viewing of measured and sourced values, streamlining calibration workflows across process plants, oil and gas, power generation, and manufacturing environments.


Technical Specifications

Voltage (DC)

  • Measure: up to 30.000 V (accuracy 0.02% + 2 counts)

  • Source: 10.000 V (accuracy 0.02% + 2 counts)

  • mV range: −10.00 mV to 75.00 mV via TC connector (accuracy 0.025% + 1 count) Current (mA)

  • Measure, Source, and Simulate: 24.000 mA (accuracy 0.02% + 2 counts) Resistance (Ohms)

  • Measure and Source range: 15 to 3200 Ω

  • Measure accuracy (0.0–400.0 Ω): 0.1 Ω (4-wire), 0.15 Ω (2- and 3-wire)

  • Measure accuracy (401–1500 Ω): 0.5 Ω (4-wire), 1 Ω (2- and 3-wire)

  • Measure accuracy (1500–3200 Ω): 1 Ω (4-wire), 1.5 Ω (2- and 3-wire)

  • Source accuracy: 0.15 Ω (15.0–400.0 Ω at 0.15–0.5 mA excitation), 0.1 Ω (0.5–2 mA excitation); 0.5 Ω (401–1500 Ω at 0.05–0.8 mA); 1 Ω (1500–3200 Ω at 0.05–0.4 mA); 1% base accuracy Temperature

  • RTD types: Ni120, Pt100 (385, 393, JIS)

  • Thermocouple types: J, K, T, E, R, S, B, L, U, N

  • TC measure accuracy: 0.2°C cold junction uncertainty; individual type accuracy 0.1°C to 1.4°C depending on type

  • RTD measure accuracy: 0.1°C to 0.33°C depending on type

  • RTD source accuracy: 0.2°C to 0.33°C depending on type

  • Temperature coefficient: ±0.005% of range per °C


Key Features



  • Split-screen display for simultaneous measurement and sourcing readout

  • Compact, portable design for field deployment

  • 4-wire, 2-wire, and 3-wire resistance measurement modes

  • Thermocouple cold junction compensation

  • Multi-standard RTD support


Typical Applications



  • Process instrumentation calibration

  • Control loop troubleshooting

  • Transmitter verification

  • Temperature sensor validation

  • Plant maintenance and commissioning


Compatibility & Integration TC connector interface for thermocouple and mV measurements. Supports industry-standard RTD and thermocouple standards for integration into existing process systems.

Specifications

ParameterValue
Voltage / Current Range0–10 V (source)

Fluke 725 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Fluke 725. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Fluke 725 price

This Fluke 725 is listed at $4,160. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Fluke 725 calibration cost

NIST-traceable calibration for the Fluke 725 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents