Fluke 80E-10 Voltage Divider – 10 kV max.

The Fluke 80E-10 is a voltage divider designed to extend the measurement capability of multimeters to 10 kV. This allows standard multimeters to measure high voltage signals, such as those found in electrical power distribution systems and high-voltage equipment.

Model
Fluke 8.00E-09
Calibration
Available on request
Price
$450
Status
In stock
RFQ ref
8.00E-09
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Fluke 80E-10 is a precision high-voltage divider that extends multimeter measurement capabilities to 10 kV DC. It converts high-voltage signals into proportional low-voltage outputs suitable for differential voltmeters and null-type potentiometers, making it essential for characterizing power distribution systems and high-voltage equipment. The instrument features precision wirewound resistors with low temperature coefficient and achieves 0.01% division ratio accuracy within the 18°C to 28°C operating band.

Technical Specifications

Maximum Input Voltage: 10 kV DC

Division Ratios: Divide by 1,000 and divide by 10,000

Output Terminals: 10 V and 1 V proportional outputs on binding posts (3/4" centers)

Division Ratio Accuracy: ±0.01% (18°C to 28°C); 2 ppm/°C outside this range (0°C to 50°C)

Division Ratio Stability: ±0.01% per year after internal recalibration

Panel Meter Accuracy: Approximately 3% of full scale

Operating Temperature Range: 0°C to 50°C

Input Impedance: Infinite impedance required for specified accuracy; 10 MΩ voltmeters introduce ~0.1% loading error on 10 V output

Input Connector: MS3102A-18-165 (mating connector supplied)

Dimensions: 7" H × 8.5" W × 8" D

Weight: Approximately 6 pounds

Key Features

Center-zero panel meter for magnitude and polarity indication

Precision wirewound resistive elements with low temperature coefficient

Separate grounding binding post on front panel

Connector shell connected to chassis ground

Meets MIL-T-945A vibration specifications

Meets MIL-E-4970A shock requirements (half sine: 20 g, 11 milliseconds)

Typical Applications

Electrical power distribution system measurements

High-voltage equipment characterization

High-voltage signal precision measurement

Compatibility & Integration Designed for use with Fluke differential voltmeters or null-type potentiometers. Fluke differential voltmeters offer infinite input impedance at null, eliminating loading errors. Case suitable for both bench use and rack mounting.

Specifications

ParameterValue
Voltage / Current Range10 kV DC input

Fluke 8.00E-09 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Fluke 8.00E-09. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Fluke 8.00E-09 price

This Fluke 8.00E-09 is listed at $450. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Fluke 8.00E-09 calibration cost

NIST-traceable calibration for the Fluke 8.00E-09 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →