Fluke 80E-10 Voltage Divider – 10 kV max.
The Fluke 80E-10 is a voltage divider designed to extend the measurement capability of multimeters to 10 kV. This allows standard multimeters to measure high voltage signals, such as those found in electrical power distribution systems and high-voltage equipment.
- Model
- Fluke 8.00E-09
- Calibration
- Available on request
- Price
- $450
- Status
- In stock
- RFQ ref
- 8.00E-09
This unit
The Fluke 80E-10 is a precision high-voltage divider that extends multimeter measurement capabilities to 10 kV DC. It converts high-voltage signals into proportional low-voltage outputs suitable for differential voltmeters and null-type potentiometers, making it essential for characterizing power distribution systems and high-voltage equipment. The instrument features precision wirewound resistors with low temperature coefficient and achieves 0.01% division ratio accuracy within the 18°C to 28°C operating band.
Technical Specifications
Maximum Input Voltage: 10 kV DC
Division Ratios: Divide by 1,000 and divide by 10,000
Output Terminals: 10 V and 1 V proportional outputs on binding posts (3/4" centers)
Division Ratio Accuracy: ±0.01% (18°C to 28°C); 2 ppm/°C outside this range (0°C to 50°C)
Division Ratio Stability: ±0.01% per year after internal recalibration
Panel Meter Accuracy: Approximately 3% of full scale
Operating Temperature Range: 0°C to 50°C
Input Impedance: Infinite impedance required for specified accuracy; 10 MΩ voltmeters introduce ~0.1% loading error on 10 V output
Input Connector: MS3102A-18-165 (mating connector supplied)
Dimensions: 7" H × 8.5" W × 8" D
Weight: Approximately 6 pounds
Key Features
Center-zero panel meter for magnitude and polarity indication
Precision wirewound resistive elements with low temperature coefficient
Separate grounding binding post on front panel
Connector shell connected to chassis ground
Meets MIL-T-945A vibration specifications
Meets MIL-E-4970A shock requirements (half sine: 20 g, 11 milliseconds)
Typical Applications
Electrical power distribution system measurements
High-voltage equipment characterization
High-voltage signal precision measurement
Compatibility & Integration Designed for use with Fluke differential voltmeters or null-type potentiometers. Fluke differential voltmeters offer infinite input impedance at null, eliminating loading errors. Case suitable for both bench use and rack mounting.
Specifications
| Parameter | Value |
|---|---|
| Voltage / Current Range | 10 kV DC input |
Fluke 8.00E-09 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Fluke 8.00E-09. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Fluke 8.00E-09 price
This Fluke 8.00E-09 is listed at $450. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Fluke 8.00E-09 calibration cost
NIST-traceable calibration for the Fluke 8.00E-09 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →