Baker Hughes / Panametrics 80CAL-TB2 1/8" Magna-Mike Calibration Fixture
Baker Hughes / Panametrics Calibration Equipment.
- Model
- Baker Hughes / Panametrics 80CAL-TB2
- Calibration
- Available on request
- Price
- $450
- Status
- In stock
- RFQ ref
- 80CAL-TB2
This unit
The Baker Hughes / Panametrics 80CAL-TB2 is a 1/8" (3.17 mm) diameter calibration fixture engineered to establish known reference standards for Panametrics Magna-Mike thickness gauges. This precision-machined steel target ball fixture enables accurate, repeatable calibration by providing a consistent gap measurement reference point. The gauge's Hall-effect sensor measures the distance between the magnetic probe tip and the target ball, converting that gap into a thickness reading. Calibration with the 80CAL-TB2 ensures the instrument's magnetic field sensor maintains measurement accuracy across applications.
Technical Specifications
Target Ball Diameter: 1/8" (3.17 mm)
Material: Precision-machined steel
Design: Calibration fixture / target ball assembly
Measurement Method: Hall-effect magnetic sensing of probe-to-target gap distance
Intended Use: Calibration standard for Panametrics Magna-Mike thickness gauging instruments
Key Features
Provides known, consistent reference standard for instrument calibration
Compatible with magnetic probe measurement systems
Part of a comprehensive calibration accessory ecosystem
Enables verification of sensor accuracy and linearity
Typical Applications
Initial instrument calibration and setup
Periodic recalibration verification
Quality assurance in thickness measurement protocols
Maintenance of measurement traceability
Compatibility & Integration The 80CAL-TB2 integrates with Magna-Mike 8500 and 8600 series thickness gauges. It functions within a broader calibration kit family that includes additional target ball sizes (80CAL-TB1, 80CAL-TB3) and fixed-thickness calibration standards (80CAL-010 through 80CAL-300), as well as NIST-traceable calibration references. The 1/8" target ball size corresponds to the calibration ball included in the Magna-Mike 8600 kit.
Baker Hughes / Panametrics 80CAL-TB2 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Baker Hughes / Panametrics 80CAL-TB2. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Baker Hughes / Panametrics 80CAL-TB2 price
This Baker Hughes / Panametrics 80CAL-TB2 is listed at $450. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Baker Hughes / Panametrics 80CAL-TB2 calibration cost
NIST-traceable calibration for the Baker Hughes / Panametrics 80CAL-TB2 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →