Agilent/Keysight 81606A Tunable Laser Module (1240–1380 nm)

Agilent / Keysight Tunable Laser Sources. Accuracy: ±1.5 pm typical, Wavelength: dependent system testing in telecommunications and.

Model
Agilent / Keysight 81606A
Calibration
Available on request
Price
$15,899
Status
In stock
RFQ ref
81606A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Keysight 81606A is a tunable laser module engineered for the 8164B lightwave measurement system, delivering precision wavelength control across the 1240–1380 nm band. It has sub-picometer tuning repeatability, exceptional spectral purity, and bidirectional sweep speeds up to 200 nm/s - 40 times faster than predecessor models. The module excels in component characterization, system validation, and optical network testing, where absolute accuracy and dynamic range are critical.


Technical Specifications



  • Wavelength Range: 1240–1380 nm (standard configuration; additional bands available via options)

  • Sweep Speed: Up to 200 nm/s bidirectional

  • Maximum Output Power: > +13 dBm peak (Option 113); > +12 dBm peak (other configurations); user-adjustable to 0 dBm minimum

  • Absolute Wavelength Accuracy: ±1.5 pm typical

  • Wavelength Repeatability: ±1 pm typical during two-way sweeps to 200 nm/s

  • Spectral Width: 50 dB

  • Signal-to-Spontaneous Emission Ratio: ≥ 80 dB/nm typical

  • Tuning Repeatability: Sub-picometer

  • Optical Connector: FC/PC (angled contact option available)

  • Electrical Connectors: Two BNC connectors (input/output); maximum ±6 V per connector


Key Features



  • 4-fold improvement in absolute wavelength accuracy versus earlier generations

  • 15 dB greater dynamic range compared to predecessor models

  • 10 dB reduction in source spontaneous emission

  • Bidirectional sweep capability with sub-picometer repeatability across full tuning range

  • Compact module design fits into the bottom back-loadable slot of the 8164B mainframe


Typical Applications



  • Optical component characterization and validation

  • Wavelength-dependent system testing in telecommunications and networking

  • Photonic research requiring high spectral purity and tuning precision

  • Automated wavelength sweeping and parametric testing


Compatibility & Integration The 81606A integrates into the Keysight 8164B Lightwave Measurement System mainframe. It is compatible with current 81600B laser commands and operates under the N7700A photonic application suite software.

Agilent / Keysight 81606A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight 81606A. Calibration covers wavelength accuracy at 5 or more points across the full tuning range, mode-hop-free range, output power flatness, linewidth, and side-mode suppression ratio (SMSR). All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Agilent / Keysight 81606A faults: output power drift, mode hops, fiber pigtail connector damage, wavelength inaccuracy. Common faults include output power drift after extended use, mode hops at specific wavelengths, and fiber pigtail connector damage. Full alignment and piezo calibration typically restore performance to spec.

Agilent / Keysight 81606A price

This Agilent / Keysight 81606A is listed at $15,899. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Agilent / Keysight 81606A calibration cost

NIST-traceable calibration for the Agilent / Keysight 81606A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers wavelength accuracy at 5 or more points across the full tuning range, mode-hop-free range, output power flatness, linewidth, and side-mode suppression ratio (SMSR). Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents