Agilent / Keysight Tunable Laser Sources. Accuracy: Specified in picometers (pm), Power Range: Specified in dBm or milliwatts (mW), Accuracy: Specified in dB or %.
- Model
- Agilent / Keysight 81640B
- Calibration
- Available on request
- Price
- $13,019
- Status
- In stock
- RFQ ref
- 81640B
This unit
The Agilent/Keysight 81640B is a continuous wave tunable laser source engineered for optical component testing, metrology, and research. It delivers stable, precise optical power across tunable wavelengths with narrow linewidth performance. The instrument supports both internal and external modulation, making it suitable for complex optical system characterization in laboratory and integration environments.
Technical Specifications
Laser Output- Type: Continuous Wave (CW) Tunable Laser Source
- Wavelength Range: Module-dependent
- Tuning Speed: Module-dependent
- Wavelength Accuracy: Specified in picometers (pm)
- Wavelength Stability: Specified in pm/°C or pm/hour
- Linewidth: Specified in kHz or MHz
- Output Power Range: Specified in dBm or milliwatts (mW)
- Power Stability: Specified in dB or % per hour/minute
- Power Accuracy: Specified in dB or %
- Polarization: Single-mode or multi-mode fiber output with polarization extinction ratio (PER)
- Mode Field Diameter (MFD): Approximately 9 µm for standard single-mode fiber
- Return Loss: Specified in dB Modulation Capabilities
- Amplitude Modulation (AM): Internal or external, frequency and depth specified by module
- Frequency Modulation (FM): Internal or external, frequency range and deviation specified by module
- On/Off Modulation: Pulsed operation with specified switching speeds
Key Features
- Narrow spectral linewidth for high-resolution spectroscopy and interferometry
- Tunable wavelength operation across module-specific ranges
- Long-term and short-term wavelength stability for precision measurements
- Flexible modulation options for dynamic optical testing
- Single-mode and multi-mode fiber output configurations
- Return loss performance optimized to prevent laser instability
Typical Applications
- Optical component characterization and device testing
- Spectroscopic measurements requiring narrow linewidth sources
- Interferometric metrology and optical system development
- Research environments demanding wavelength-tunable CW sources
Compatibility & Integration
- Control Interface: GPIB (IEEE 488.2), SCPI command language
- Standard rack-mountable or benchtop form factors
- Warm-up time required to reach stable operating parameters
Agilent / Keysight 81640B — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight 81640B. Calibration covers wavelength accuracy at 5 or more points across the full tuning range, mode-hop-free range, output power flatness, linewidth, and side-mode suppression ratio (SMSR). All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Agilent / Keysight 81640B faults: output power drift, mode hops, fiber pigtail connector damage, wavelength inaccuracy. Common faults include output power drift after extended use, mode hops at specific wavelengths, and fiber pigtail connector damage. Full alignment and piezo calibration typically restore performance to spec.
Agilent / Keysight 81640B price
This Agilent / Keysight 81640B is listed at $13,019. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Agilent / Keysight 81640B calibration cost
NIST-traceable calibration for the Agilent / Keysight 81640B is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers wavelength accuracy at 5 or more points across the full tuning range, mode-hop-free range, output power flatness, linewidth, and side-mode suppression ratio (SMSR). Turnaround is 1 to 3 business days after receipt. See full calibration details →