Agilent/Keysight 8482B
Agilent / Keysight RF Power Sensors. Frequency Range: 100 kHz to 4.2 GHz.
- Model
- Agilent / Keysight 8482B
- Calibration
- Available on request
- Price · starting from
- $639
- Status
- In stock
- RFQ ref
- 8482B
This unit
The Agilent/Keysight 8482B is a thermocouple power sensor delivering precise average power measurements from 100 kHz to 4.2 GHz. It measures power levels from 1 mW to 25 W across dual dynamic ranges, with less than 1% power linearity and NIST-traceable calibration. This sensor is engineered for RF and microwave test environments where measurement accuracy and low SWR are critical.
Technical Specifications
- Frequency Range: 100 kHz to 4.2 GHz
- Power Measurement Range: 0 dBm to +44 dBm (1 mW to 25 W)
Low power path: −30 dBm to +20 dBm
High power path: +20 dBm to +44 dBm
- Impedance: 50 ohms
- Connector: Type-N male, precision connector with D-ring safety feature
- Sensing Element: Thermocouple
- Power Linearity: Less than 1% (±0.15%/°C temperature coefficient post-calibration)
- Calibration: NIST-traceable
- Dimensions: 4.5 in (H) × 3.3 in (W) × 11.14 in (L)
- Weight: 1.51 lbs
Key Features
- Low SWR minimizes mismatch uncertainty in high-impedance test setups
- Dual-path design optimizes accuracy across wide dynamic range
- High power configuration (25 W) integrates 30 dB attenuator assembly with sensor; attenuator and sensor must be used together for specified performance
- D-ring connector design prevents connection to high-power sources without required attenuator
- Suitable for communication systems, radar, and electronic warfare testing
Compatibility & Integration The 8482B interfaces with EPM, EPM-P, and P-Series power meters, legacy 435A/B, 436A, 437A, and 438A units, plus 70100A, E1416A VXI, and N1911A/N1912A/N1913A/N1914A instruments. When used with 8480 Series Power Meters, Option CFT enables SCPI compatibility. Incompatible meters: 43x, E1416A, N8262A, 5314x microwave counters, E7495x base station test sets. Note: High power attenuator may contain beryllium oxide. Do not generate dust; return defective units to Agilent for disposal.
Agilent / Keysight 8482B — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight 8482B. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Agilent / Keysight 8482B price
This Agilent / Keysight 8482B is listed at $639. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Agilent / Keysight 8482B calibration cost
NIST-traceable calibration for the Agilent / Keysight 8482B is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →