Digital Lightwave NIC NXG ALLN88NL81B PORTABLE NETWORK INFORMATION,Combination test module integrating NL81B and N88 capabilities. Offers complete testing solution for modern networks with flexible configuration options. Includes advanced analysis tools covering wide range of network testing requirements.
- Model
- Digital Lightwave ALLN88NL81B
- Calibration
- Available on request
- Price · starting from
- $2,630
- Status
- In stock
- RFQ ref
- ALLN88NL81B
This unit
The Digital Lightwave NIC NXG ALLN88NL81B is a portable network information computer engineered for verification and qualification of multi-protocol communication networks. This 2-slot platform integrates NL81B and N88 test modules, delivering comprehensive testing across Ethernet, Fibre Channel, OTN, SONET/SDH, and PDH/DSn protocols. The NIC NXG supports data rates from 64 kbps through 112 Gbps, making it suitable for carrier-grade network validation across legacy and infrastructure.
Technical Specifications
Protocol Support- OTN: All G.709 rates from 2.6 Gbps to 112 Gbps; OTU4, OTU3, OTU3e1/e2, OTU2f/e1f, OTU2e/e1e, OTU2, OTU1; OTL layer testing at 40/100 Gbps; unframed BERT
- SONET/SDH: Up to OC-48/STM-16
- Carrier Ethernet: MPLS with RFC 2544 and APS testing (license-based)
- Data Rate Range: 64 kbps through 112 Gbps multi-rate capability Electrical
- Input Voltage: 90–264 VAC, 50–60 Hz nominal
- Power Dissipation: 150 W (NIC chassis)
- Laser Safety: Class 1 laser devices; protective covers required on optical connectors Interfaces
- Network: 10/100/1000BASE-T
- Clock Reference: Internal Stratum 3; BITS/SETS/2.048 MHz Bantam/BNC clock in/out
- Ports: 3× USB, SD/SDHC slot, DE-15 VGA, trigger in/out, optional 802.11 wireless via USB
- Storage: Removable industrial-grade compact flash module Physical
- Height: 257 mm (2-slot configuration)
Key Features
- Modular test architecture accommodates PDH/T-Carrier, MSA 2020/2030, optical jitter/wander, CSA 4100 40G/100G, OSA C/L-Band, serial interface, ATM, and Gigabit Ethernet modules
- FEC generation and analysis for OTN testing
- Internal Stratum 3 clock reference with external clock synchronization
- Industrial-grade storage for operating system persistence
- Portable form factor with external display connectivity
Typical Applications
- OTN signal validation from 2.6 Gbps to 112 Gbps
- SONET/SDH network commissioning and troubleshooting
- Carrier Ethernet MPLS testing with RFC 2544 compliance verification
- Multi-protocol network performance characterization
Compatibility & Integration The NIC NXG scales within the NIC platform family, which includes battery-pack variants (NIC BP), 5-slot configurations (NIC Plus NXG, NIC EP), and rackmount options. Test module selection determines specific protocol and data rate capabilities within the 64 kbps to 112 Gbps envelope.
Specifications
| Parameter | Value |
|---|---|
| Voltage / Current Range | 50–60 Hz, 90–264 VAC |
Digital Lightwave ALLN88NL81B — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Digital Lightwave ALLN88NL81B. Calibration covers analog input channel accuracy and offset at all gain settings, analog output accuracy, digital I/O logic threshold verification, sample rate and timing accuracy, and trigger and synchronization bus functional verification. NI CompactRIO and PXI chassis also undergo backplane trigger line integrity check.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Digital Lightwave ALLN88NL81B faults: power supply failure (cRIO-9073/9074), C-series slot connector wear, PXI chassis fan failure, GPIB interface failure on VXI controllers, BIOS/EEPROM corruption. NI CompactRIO most common faults are power supply failure on older cRIO-9073/9074 chassis and C-series module slot connector wear from repeated hot-swap cycles. PXI chassis fan failure is the most common wear item — chassis fans are field-replaceable. VXI embedded controllers most commonly develop EEPROM corruption and GPIB interface failure.
Digital Lightwave ALLN88NL81B price
This Digital Lightwave ALLN88NL81B is listed at $2,630. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Digital Lightwave ALLN88NL81B calibration cost
NIST-traceable calibration for the Digital Lightwave ALLN88NL81B is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers analog input channel accuracy and offset at all gain settings, analog output accuracy, digital I/O logic threshold verification, sample rate and timing accuracy, and trigger and synchronization bus functional verification. NI CompactRIO and PXI chassis also undergo backplane trigger line integrity check.. Turnaround is 1 to 3 business days after receipt. See full calibration details →