Yokogawa AQ1205E 1310/1550/1625nm OTDR Multi Field Tester
The Yokogawa AQ1205E is a versatile Optical Time Domain Reflectometer (OTDR) designed for field testing and troubleshooting optical fiber networks. It operates at 1310nm, 1550nm, and 1625nm wavelengths, providing comprehensive fiber characterization. This multi-wavelength capability enables technicians to detect and locate faults, measure fiber length, and assess optical return loss with precision. Ideal for ensuring the integrity and performance of optical communication systems.
- Model
- Yokogawa AQ1205E
- Calibration
- Available on request
- Price
- $4,779
- Status
- In stock
- RFQ ref
- AQ1205E
This unit
The Yokogawa AQ1205E is a handheld Optical Time Domain Reflectometer (OTDR) designed for installation, commissioning, and maintenance of single-mode fiber networks. Operating across three wavelengths - 1310 nm, 1550 nm, and 1625 nm - this compact instrument delivers dynamic range up to 40 dB and 0.75 m event resolution, enabling precise fault location and attenuation measurements on both dark fiber and live PON systems. The 1625 nm port includes a built-in cutoff filter, permitting non-disruptive testing on in-service networks.
Weighing approximately 1 kg with A5-size form factor, the AQ1205E integrates OTDR measurement with optional light source, power meter, fault locator, and fiber inspection capabilities. Field measurements can be logged to internal or USB storage and exported as CSV reports.
Technical Specifications
- Wavelengths: 1310 nm (±25 nm), 1550 nm (±25 nm), 1625 nm (±10 nm or ±25 nm)
- Fiber Type: Single-mode (ITU-T G.652)
- Dynamic Range: 40 dB typical at 1310 nm; 38 dB typical at 1550 nm; 33–36 dB at 1625 nm (guaranteed)
- Event Dead Zone: 0.75 m typical
- Attenuation Dead Zone: 4–5 m typical
- Spatial Resolution: 0.75 m
- 1625 nm Cutoff Filter: Integrated for live-network operation
- PON Measurement Mode: Optimized for splitter networks with controlled undershoot
Key Features
- Tri-wavelength capability for installation and maintenance workflows
- High-resolution measurement distinguishing closely-spaced connectors
- Wide dynamic range accommodating long spans and high-loss PON architectures
- Built-in 1625 nm filter enabling testing on active signals
- Compact, portable design approximately A5 size, ~1 kg
- Optional modules: light source, optical power meter (standard/PON/high-power variants), automatic loss measurement, multi-fiber loss measurement, visible light source, fault locator, IP test, fiber inspection probe
- USB Type B and optional Ethernet connectivity
- CSV data export
Typical Applications
- Single-mode fiber installation and acceptance testing
- PON network commissioning and troubleshooting
- Live-network maintenance via 1625 nm wavelength
- Fault localization and splice-loss characterization
- Long-distance span verification
Compatibility & Integration
- Conforms to ITU-T G.652 single-mode fiber specifications
- USB and optional Ethernet interfaces for data transfer and remote operation
Specifications
| Parameter | Value |
|---|---|
| Wavelength Range | 1310 nm (±25 nm), 1550 nm (±25 nm), 1625 nm (±10 nm or ±25 nm) |
Yokogawa AQ1205E — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Yokogawa AQ1205E. Calibration covers distance accuracy verified against a calibrated fiber length reference, event loss measurement accuracy at splice and connector events, dead zone (event and attenuation) at rated pulse width, dynamic range verification at 1310 nm and 1550 nm, backscatter coefficient calibration, and return loss measurement accuracy. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Yokogawa AQ1205E faults: optical port connector damage or contamination, battery failure, display damage from field use, module failure on FTB or MTS platforms, calibration drift. Most field OTDRs fail due to physical damage. On modular platforms (EXFO FTB, Viavi MTS), individual module failures are serviced without replacing the entire mainframe. Optical port cleaning resolves many apparent measurement faults before mechanical repair is needed.
Yokogawa AQ1205E price
This Yokogawa AQ1205E is listed at $4,779. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Yokogawa AQ1205E calibration cost
NIST-traceable calibration for the Yokogawa AQ1205E is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers distance accuracy verified against a calibrated fiber length reference, event loss measurement accuracy at splice and connector events, dead zone (event and attenuation) at rated pulse width, dynamic range verification at 1310 nm and 1550 nm, backscatter coefficient calibration, and return loss measurement accuracy. Turnaround is 1 to 3 business days after receipt. See full calibration details →