Yokogawa AQ2200-222 800-1700nm Dual Sensor Module
The Yokogawa AQ2200-222 is a dual sensor module designed for the AQ2200 Multi Application Test System. It operates in the 800-1700nm wavelength range, making it suitable for a variety of optical communication applications. This module allows for simultaneous measurement of optical power and wavelength, enhancing testing efficiency.
- Model
- Yokogawa AQ2200-222
- Calibration
- Available on request
- Price
- $2,555
- Status
- In stock
- RFQ ref
- AQ2200-222
This unit
The Yokogawa AQ2200-222 is a dual-channel optical power measurement module for the AQ2200 Multi Application Test System. Operating across 800–1700 nm, it delivers simultaneous measurements from two independent sensors within a single slot, enabling cost-effective multi-port configurations. With a minimum sampling period of 100 µs and low polarization dependency, the module addresses high-throughput testing demands across optical communication applications.
Technical Specifications
- Wavelength Range: 800–1700 nm
- Power Range: −90 to +15 dBm
- Minimum Sampling Period: 100 µs
- Number of Channels: 2 (dual sensors)
- Polarization Dependency: Low
- Slot Occupancy: 1 slot (AQ2200 Frame Controller)
Key Features
- Dual independent sensors in a single-slot module
- High-speed sampling at 10 kHz minimum rate (100 µs period)
- Simultaneous dual-channel measurement capability
- Low polarization-dependent loss characteristics
- Multi-connector support: FC, SC, MU, and LC compatibility
Typical Applications
- Optical power measurement in WDM and DWDM systems
- Multi-port component testing in manufacturing and field environments
- Broadband optical communication system characterization
- Cost-optimized test setups requiring simultaneous dual-channel acquisition
Compatibility & Integration The AQ2200-222 integrates with AQ2211 and AQ2212 Frame Controllers, enabling flexible modular system assembly. Combines with other AQ2200 series modules - light sources, attenuators, and switches - to build customized measurement systems. Compatible with broader Yokogawa optical communication test instruments for expanded measurement capability.
Specifications
| Parameter | Value |
|---|---|
| Power Range (dBm) | −90 to +15 dBm | Wavelength Range: 800–1700 nm |
Yokogawa AQ2200-222 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Yokogawa AQ2200-222. Calibration covers detector responsivity across all specified wavelengths (typically 800-1700 nm range), absolute power accuracy, and EEPROM calibration coefficient update. Compatible with Agilent/HP 8163A/B, 8164A/B, and 8166A/B mainframes.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Yokogawa AQ2200-222 faults: FC/PC connector damage, EEPROM failure (mainframe shows unrecognized sensor), reduced responsivity. Common faults include FC/PC input connector damage, EEPROM failure causing the module to appear unrecognized by the mainframe, and reduced detector responsivity from contamination.
Yokogawa AQ2200-222 price
This Yokogawa AQ2200-222 is listed at $2,555. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Yokogawa AQ2200-222 calibration cost
NIST-traceable calibration for the Yokogawa AQ2200-222 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers detector responsivity across all specified wavelengths (typically 800-1700 nm range), absolute power accuracy, and EEPROM calibration coefficient update. Compatible with Agilent/HP 8163A/B, 8164A/B, and 8166A/B mainframes.. Turnaround is 1 to 3 business days after receipt. See full calibration details →