Ando AQ2732 700-1700nm Optical Power Sensor Module
Ando Optical Power Sensors. Accuracy: ±5% (1000 nm to 1600 nm).
- Model
- Ando AQ2732
- Calibration
- Available on request
- Price
- $679
- Status
- In stock
- RFQ ref
- AQ2732
This unit
The Ando AQ2732 is a precision optical power sensor module engineered for accurate measurements across the 700 nm to 1700 nm spectral range. Built on an InGaAs photoreceptor, it delivers reliable power readings in continuous-wave and chopped signal modes - essential for optical communication system testing, laser diode characterization, and quality control workflows. The module combines wide dynamic range with tight accuracy specifications, making it suitable for both development environments and production monitoring.
Technical Specifications
- Wavelength Range: 700 nm to 1700 nm
- Photoreceptor: InGaAs
- Power Range (CW): −80 dBm to +10 dBm
- Power Range (Chopped): −90 dBm to +7 dBm
- Power Range (Optical Fiber Emission): −73 dBm to +10 dBm; −93 dBm to +10 dBm
- Total Accuracy: ±5% (1000 nm to 1600 nm)
- Accuracy (Reference): ±2.5%
- Linearity: ±0.05 dB
- Polarization Dependency Loss: 0.02 dB
- Operating Modes: Continuous Wave (CW) and chopped signal measurement
Key Features
- Wide spectral coverage from near-infrared to mid-infrared wavelengths
- Dual-mode operation accommodates both steady-state and modulated signal sources
- InGaAs detector technology provides sensitivity across the full measurement range
- Low polarization-dependent loss ensures consistent readings regardless of signal polarization
- Tight linearity specification supports high-fidelity power trending and analysis
Typical Applications
- Optical communication system testing and performance verification
- Laser diode power characterization and stability monitoring
- Research and development in optical component design
- Production quality control for optical subsystems
- Optical power monitoring across telecom and datacom wavelengths
Compatibility & Integration The AQ2732 integrates with Ando optical measurement systems and frames. Optional connector adapters - including the AQ9389B (FC), AQ9335, and AQ9433 - enable connection to common fiber optic terminations such as FC, SC, ST, DIN, and HMS-10/A. Compatible with multimode fiber configurations (GI 62.5/125 µm).
Specifications
| Parameter | Value |
|---|---|
| Power Range (dBm) | −80 dBm to +10 dBm (CW) |
| −73 dBm to +10 dBm and −93 dBm to +10 dBm (Optical Fiber Emission) | Wavelength Range | 700 nm to 1700 nm |
Ando AQ2732 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Ando AQ2732. Calibration covers detector responsivity across all specified wavelengths (typically 800-1700 nm range), absolute power accuracy, and EEPROM calibration coefficient update. Compatible with Agilent/HP 8163A/B, 8164A/B, and 8166A/B mainframes.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Ando AQ2732 faults: FC/PC connector damage, EEPROM failure (mainframe shows unrecognized sensor), reduced responsivity. Common faults include FC/PC input connector damage, EEPROM failure causing the module to appear unrecognized by the mainframe, and reduced detector responsivity from contamination.
Ando AQ2732 price
This Ando AQ2732 is listed at $679. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Ando AQ2732 calibration cost
NIST-traceable calibration for the Ando AQ2732 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers detector responsivity across all specified wavelengths (typically 800-1700 nm range), absolute power accuracy, and EEPROM calibration coefficient update. Compatible with Agilent/HP 8163A/B, 8164A/B, and 8166A/B mainframes.. Turnaround is 1 to 3 business days after receipt. See full calibration details →