Ando AQ8201-13 ECL Light Source Module
Ando Optical Light Sources. Resolution: ** 10 pm, Accuracy: ** ± 0.2 nm.
- Model
- Ando AQ8201-13
- Calibration
- Available on request
- Price
- $779
- Status
- In stock
- RFQ ref
- AQ8201-13
This unit
The Ando AQ8201-13 is an ECL (Edge-Coupled Laser) light source module engineered for optical component characterization and DWDM system verification. This plug-in module integrates into Ando AQ8200 series mainframes
AQ8201A, AQ8203, AQ8202, and AQ8204 - to deliver tunable, spectrally pure output across the C-band and adjacent wavelengths. It excels in specification evaluation of DWDM elements including MUX/DEMUX, AWG, and EDFA subsystems.
Technical Specifications
Wavelength Range: 1460 nm to 1580 nm
Wavelength Resolution: 10 pm
Wavelength Accuracy: ± 0.2 nm
Optical Output Power: +6 dBm typical; +10.3 dBm maximum
Spectral Linewidth: 100 MHz (coherence control ON) / 5 MHz (coherence control OFF)
Optical Power Stability: ± 0.005 dB
Output Fiber: Single-mode 9/125 µm, FC/APC connector
Laser Class: IEC825 Class 3A
Operating Temperature: 5 to 40 °C
Storage Temperature: 0 to 50 °C
Humidity: ≤ 85 % RH (non-condensing)
Module Dimensions: 39.5 mm (W) × 130 mm (H) × 339 mm (D)
Module Weight: 0.7 kg
Key Features
Tunable output across 1460–1580 nm with 10 pm resolution
Ultra-narrow linewidth down to 5 MHz for coherent and precision measurements
Exceptional power stability of ± 0.005 dB for repeatable characterization
Single-mode fiber delivery via industry-standard FC/APC interface
GPIB control (IEEE-488.2) via mainframe for automated test sequences
Typical Applications
DWDM component specification validation
Long-haul optical transmission system verification
Optical filter and multiplexer characterization
EDFA gain and noise figure measurement
Optical component R&D
Compatibility & Integration Inserts into AQ8201A (10-slot, 19-inch rack), AQ8203 (3-slot halfsize), AQ8202, or AQ8204 mainframes. Mainframe GPIB port enables remote command and monitoring. AQ8201A accepts 3–10 modules depending on configuration; AQ8203 accommodates up to 3 modules.
Specifications
| Parameter | Value |
|---|---|
| Power Range (dBm) | '+10.3 dBm maximum, +6 dBm typical | Voltage / Current Range: 50/60 Hz, AC 100–120 V (±10 %) / 200–240 V (±10 %) | Wavelength Range: 1460 nm to 1580 nm |
Ando AQ8201-13 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Ando AQ8201-13. Calibration covers output power at specified wavelengths, wavelength accuracy, 15-minute output stability, and modulation frequency accuracy where applicable. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Ando AQ8201-13 faults: laser diode end-of-life (output below spec), fiber output connector damage, output instability. Common repairs include laser diode replacement when output falls below spec, fiber output connector repair, and thermal management service.
Ando AQ8201-13 price
This Ando AQ8201-13 is listed at $779. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Ando AQ8201-13 calibration cost
NIST-traceable calibration for the Ando AQ8201-13 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output power at specified wavelengths, wavelength accuracy, 15-minute output stability, and modulation frequency accuracy where applicable. Turnaround is 1 to 3 business days after receipt. See full calibration details →