This unit
The Digital Lightwave ASA 312 Network Information Computer is a portable analyzer engineered for verification and qualification of telecommunications networks across DS0 through OC-48c protocols. It delivers simultaneous and independent testing of T-Carrier, SONET, and ATM signals - consolidating multiple traditional test sets into a single modular platform. The instrument features a 9.5-inch color touch-screen GUI with remote control capability, built-in optical and electrical measurements, and SONET through-mode operation with overhead manipulation. Its flexible architecture supports field installation, monitoring, and maintenance workflows across evolving network environments.
Technical Specifications Protocol Support
DS0 through OC-48c
T-Carrier: DS1/E1, DS3
SONET: STS-1, OC-1, OC-3, OC-12, OC-48 with STS-3c, STS-12c, STS-48c
ATM: AAL0, AAL1, AAL5; traffic shaping; PVC/SVC; OAM; QoS measurements; HEC error generation; cell transfer delay
Internal DS1/DS3 drop/insert from SONET with integrated M13 multiplexer Optical Interfaces
SONET wavelengths: 1310 nm, 1550 nm, or switchable 1310/1550 nm
OC-1/OC-3/OC-12 configurations available with 1310 nm laser Measurements & Analysis
Optical power and frequency (built-in)
Electrical power and frequency (built-in)
Auto-configuration to pattern level
Troublescan functionality
Alarm and error generation/analysis Connectivity
10/100/1000BASE-T network interface
SCPI over GPIB, TCP/IP, or RS-232c
3× USB ports; SD/SDHC slot; external VGA output (DE-15)
PCMCIA interface for modem and memory
Remote access via RS-232 or dial-up modem
Optional 802.11 wireless via USB
Trigger in/out
Internal Stratum 3 clock; BITS/SETS/2.048 MHz Bantam/BNC clock I/O Display & Control
9.5-inch active matrix color touch-screen
Intuitive touch-sensitive GUI with remote control Physical Specifications
NIC: 257 mm H × 312 mm W × 120 mm D; 5.0–5.6 kg
NIC+: 348 mm H × 330 mm W × 201 mm D; 6.5–11.34 kg
Total weight range: 10.5–14 lbs depending on configuration
Key Features
Modular, configurable design for current deployment and future upgrades
Simultaneous, independent multi-protocol testing
Touch-screen interface and test-scripting for technician accessibility
Portable form factor optimized for field operations
Typical Applications
T-Carrier, SONET, and ATM network installation and commissioning
Circuit and path-level troubleshooting
Continuous network monitoring and maintenance
Embedded network element verification
Compatibility & Integration Supports standard remote control via SCPI command set over multiple interfaces. Wired and wireless network connectivity enable integration with centralized management systems and field diagnostic workflows.
Specifications
| Parameter | Value |
|---|---|
| Wavelength Range | 1310 nm, 1550 nm, or switchable 1310/1550 nm |
Digital Lightwave ASA — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Digital Lightwave ASA. Calibration covers optical reference power levels, electrical signal amplitude calibration, protocol layer verification, and BER measurement floor validation. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Digital Lightwave ASA faults: SFP cage mechanical damage, optical port contamination, firmware corruption. Most failures involve SFP/SFP+ cage mechanical damage, optical port contamination, or firmware corruption. Port cleaning and firmware restoration resolve the majority of faults.
Digital Lightwave ASA price
This Digital Lightwave ASA is listed at $4,500. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Digital Lightwave ASA calibration cost
NIST-traceable calibration for the Digital Lightwave ASA is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers optical reference power levels, electrical signal amplitude calibration, protocol layer verification, and BER measurement floor validation. Turnaround is 1 to 3 business days after receipt. See full calibration details →