Agilent/Keysight B2200A
Agilent / Keysight Embedded Test Systems. Voltage: 200 V, Current: 1 A, Resolution: 1 fA.
- Model
- Agilent / Keysight B2200A
- Calibration
- Available on request
- Price
- $5,590
- Status
- In stock
- RFQ ref
- B2200A
This unit
The Keysight B2200A fA Leakage Switch Mainframe is a matrix switching system that automates parametric characterization of semiconductor devices while maintaining the measurement precision of parameter analyzers. It expands the capabilities of Keysight B1500A, 4155C, and 4156C analyzers, enabling fully automated test solutions for DC characterization, capacitance, and LCR measurements across multiple device nodes.
Technical Specifications
Switching Matrix Performance- Matrix type with 100 TΩ isolation
- Maximum output voltage: 200 V
- Maximum output current: 1 A
- Minimum current measurement resolution: 1 fA
- Settling time: Under 50 fA in 2 seconds
- Capacitance measurement compensation routine corrects for internal path length distortion Input/Output Architecture
- 8 triaxial ports (supports up to 4 Kelvin triaxial ports)
- 6 coaxial BNC ports
- Up to four B2210A matrix cards per mainframe
- Scalable output configurations: x12, x24, x36, x48 via B2210A cards
- Kelvin measurement support on up to four SMUs Physical & Environmental
- Dimensions: 430 mm (W) × 320 mm (H) × 600 mm (D)
- Operating temperature: +5°C to +35°C
- Storage temperature: -20°C to +70°C
- Operating humidity: 5% to 70% RH (non-condensing)
- Power requirement: 90–264 V AC, 47–63 Hz, 2 A/200 VA maximum
Key Features
- Switches DC current, DC voltage, capacitance, and LCR meters
- VXI Plug&Play drivers with integrated capacitance compensation routine on CD-ROM
- Front-panel keypad control or optional light pen interface
- Remote control via GPIB commands
- EasyEXPERT GUI integration for automated switch configuration
- Compatible exclusively with B2210A fA leakage switch modules
Typical Applications Parametric test automation for semiconductor device and module characterization, including gate leakage current measurement, multi-point DC sweeps, and capacitance profiling across multiple device pins without sacrificing measurement resolution.
Compatibility & Integration Works with Keysight B1500A Semiconductor Device Analyzer, 4155C, and 4156C parameter analyzers. Integrates with EasyEXPERT and EasyEXPERT group+ software for complete parametric test environments.
Agilent / Keysight B2200A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight B2200A. Calibration covers analog input channel accuracy and offset at all gain settings, analog output accuracy, digital I/O logic threshold verification, sample rate and timing accuracy, and trigger and synchronization bus functional verification. NI CompactRIO and PXI chassis also undergo backplane trigger line integrity check.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Agilent / Keysight B2200A faults: power supply failure (cRIO-9073/9074), C-series slot connector wear, PXI chassis fan failure, GPIB interface failure on VXI controllers, BIOS/EEPROM corruption. NI CompactRIO most common faults are power supply failure on older cRIO-9073/9074 chassis and C-series module slot connector wear from repeated hot-swap cycles. PXI chassis fan failure is the most common wear item — chassis fans are field-replaceable. VXI embedded controllers most commonly develop EEPROM corruption and GPIB interface failure.
Agilent / Keysight B2200A price
This Agilent / Keysight B2200A is listed at $5,590. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Agilent / Keysight B2200A calibration cost
NIST-traceable calibration for the Agilent / Keysight B2200A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers analog input channel accuracy and offset at all gain settings, analog output accuracy, digital I/O logic threshold verification, sample rate and timing accuracy, and trigger and synchronization bus functional verification. NI CompactRIO and PXI chassis also undergo backplane trigger line integrity check.. Turnaround is 1 to 3 business days after receipt. See full calibration details →