The Corelis CAS-1000 is an integrated JTAG boundary-scan controller and I2C/SMBus analysis instrument designed for debug, validation, and in-system programming across development, production, and field environments. It combines real-time bus monitoring, traffic generation, device emulation, and structural testing in a single Windows-based platform.

Technical Specifications Bus Support & Data Rates

I2C and SMBus protocols

Standard-mode, Fast-mode, and Fast-mode Plus (Fm+) operation up to 5 Mbit/s Emulation & Master/Slave Operation

Simultaneous monitoring and emulation capability

Up to 1 emulated master and 10 emulated slaves concurrently

Configurable master, slave, or dual-mode operation Electrical & Timing Measurement

Graphical waveform display of I2C bus electrical and timing parameters

Adjustable bus voltage reference

Software-configurable pull-up resistors on SDA and SCL lines

Automatic measurement and verification via Parameter Scope Traffic Generation & Stress Testing

Glitch injection, protocol error generation, and slave clock stretching

Active bus override capability for UUT stress testing

Transaction generation for peripheral device communication Monitoring & Logging

Passive traffic capture with state and timing recording

Time stamping, message filtering, and symbolic translation

Unlimited continuous logging to file

Advanced trigger events for transaction isolation

Bit and protocol-level timing waveform visualization Programming & JTAG

In-system programming of I2C serial EEPROMs

Flash memory and CPLD programming (with optional ScanExpress software)

Integrated JTAG controller for boundary-scan test operations

Key Features

I2C Exerciser software with consolidated GUI for host PC control

Windows-based interface for intuitive operation

Combined I2C analysis and JTAG boundary-scan testing

Real-time visibility into bus operations

Typical Applications

Product development and debug

System integration and validation

Production testing and in-system programming

Field-level troubleshooting and maintenance

Bus specification compliance verification

Compatibility & Integration Optional Corelis ScanExpress software extends capabilities to structural boundary-scan testing and non-volatile memory programming.

Corelis CAS-1000 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Corelis CAS-1000. Calibration covers analog input channel accuracy and offset at all gain settings, analog output accuracy, digital I/O logic threshold verification, sample rate and timing accuracy, and trigger and synchronization bus functional verification. NI CompactRIO and PXI chassis also undergo backplane trigger line integrity check.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Corelis CAS-1000 faults: power supply failure (cRIO-9073/9074), C-series slot connector wear, PXI chassis fan failure, GPIB interface failure on VXI controllers, BIOS/EEPROM corruption. NI CompactRIO most common faults are power supply failure on older cRIO-9073/9074 chassis and C-series module slot connector wear from repeated hot-swap cycles. PXI chassis fan failure is the most common wear item — chassis fans are field-replaceable. VXI embedded controllers most commonly develop EEPROM corruption and GPIB interface failure.

Corelis CAS-1000 price

This Corelis CAS-1000 is listed at $3,200. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Corelis CAS-1000 calibration cost

NIST-traceable calibration for the Corelis CAS-1000 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers analog input channel accuracy and offset at all gain settings, analog output accuracy, digital I/O logic threshold verification, sample rate and timing accuracy, and trigger and synchronization bus functional verification. NI CompactRIO and PXI chassis also undergo backplane trigger line integrity check.. Turnaround is 1 to 3 business days after receipt. See full calibration details →