Burleigh DA-100 Detector Amplifier

Burleigh Signal Conditioning Modules. Bandwidth: 0.3 to 100 kHz (0.3 to 20 kHz at maximum gain) wit, Sensitivity: 0.1 V/mW to 1 V/µW.

Model
Burleigh DA-100
Calibration
Available on request
Price
$779
RFQ ref
DA-100
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Burleigh DA-100 Detector Amplifier is a precision signal conditioning instrument that amplifies weak detector outputs across visible to infrared wavelengths. It delivers low-noise amplification with continuously variable gain and selectable bandwidth, making it essential for spectroscopy, microscopy, and materials research applications. The unit integrates with Burleigh SA Plus and TL Series Fabry-Perot Laser Spectrum Analyzers to reduce laser intensity requirements during spectral analysis.


Technical Specifications



  • Bandwidth: 0.3 to 100 kHz (0.3 to 20 kHz at maximum gain) with six selectable steps: 0.3, 1, 3, 10, 30 kHz, and maximum

  • Sensitivity: 0.1 V/mW to 1 V/µW, continuously variable

  • Gain: Four decade steps (×1, ×10, ×100, ×1000) plus fine continuous adjustment

  • Minimum Detectable Power: Silicon −1 nW at 633 nm; Germanium −2 nW at 1.5 µm

  • RMS Noise: <1 mV

  • Output Signal: 0 to ±6 V into 200 Ω with invertible polarity

  • Offset Adjustment: ±1 V

  • Power Supply: Two 9 V batteries or external 9 V DC (10–12 V range recommended); batteries serve as backup with external supply


Key Features



  • Polarity invert switch for signal phase control

  • Battery check indicator

  • BNC output connector

  • Cast aluminum alloy enclosure

  • Compact form factor: 57 × 89 × 152 mm, 0.45 kg


Typical Applications Detector signal amplification in spectroscopy, laser spectrum analysis, microscopy, and materials characterization where signal-to-noise ratio and dynamic range are critical.


Compatibility & Integration Primary integration with Burleigh SA Plus and TL Series Fabry-Perot Laser Spectrum Analyzers. Interchangeable photodetector design supports operation across visible to infrared wavelength ranges.

Specifications

ParameterValue
Frequency Range0.3 to 100 kHz (0.3 to 20 kHz at maximum gain) | Voltage / Current Range: 0 to ±6 V output
9 V DC power supply (10–12 V range recommended) | Wavelength Range633 nm (silicon)

Burleigh DA-100 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Burleigh DA-100. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Burleigh DA-100 price

This Burleigh DA-100 is listed at $779. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Burleigh DA-100 calibration cost

NIST-traceable calibration for the Burleigh DA-100 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →