Burleigh DA-100 Detector Amplifier
Burleigh Signal Conditioning Modules. Bandwidth: 0.3 to 100 kHz (0.3 to 20 kHz at maximum gain) wit, Sensitivity: 0.1 V/mW to 1 V/µW.
- Model
- Burleigh DA-100
- Calibration
- Available on request
- Price
- $779
- RFQ ref
- DA-100
This unit
The Burleigh DA-100 Detector Amplifier is a precision signal conditioning instrument that amplifies weak detector outputs across visible to infrared wavelengths. It delivers low-noise amplification with continuously variable gain and selectable bandwidth, making it essential for spectroscopy, microscopy, and materials research applications. The unit integrates with Burleigh SA Plus and TL Series Fabry-Perot Laser Spectrum Analyzers to reduce laser intensity requirements during spectral analysis.
Technical Specifications
- Bandwidth: 0.3 to 100 kHz (0.3 to 20 kHz at maximum gain) with six selectable steps: 0.3, 1, 3, 10, 30 kHz, and maximum
- Sensitivity: 0.1 V/mW to 1 V/µW, continuously variable
- Gain: Four decade steps (×1, ×10, ×100, ×1000) plus fine continuous adjustment
- Minimum Detectable Power: Silicon −1 nW at 633 nm; Germanium −2 nW at 1.5 µm
- RMS Noise: <1 mV
- Output Signal: 0 to ±6 V into 200 Ω with invertible polarity
- Offset Adjustment: ±1 V
- Power Supply: Two 9 V batteries or external 9 V DC (10–12 V range recommended); batteries serve as backup with external supply
Key Features
- Polarity invert switch for signal phase control
- Battery check indicator
- BNC output connector
- Cast aluminum alloy enclosure
- Compact form factor: 57 × 89 × 152 mm, 0.45 kg
Typical Applications Detector signal amplification in spectroscopy, laser spectrum analysis, microscopy, and materials characterization where signal-to-noise ratio and dynamic range are critical.
Compatibility & Integration Primary integration with Burleigh SA Plus and TL Series Fabry-Perot Laser Spectrum Analyzers. Interchangeable photodetector design supports operation across visible to infrared wavelength ranges.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 0.3 to 100 kHz (0.3 to 20 kHz at maximum gain) | Voltage / Current Range: 0 to ±6 V output |
| 9 V DC power supply (10–12 V range recommended) | Wavelength Range | 633 nm (silicon) |
Burleigh DA-100 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Burleigh DA-100. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Burleigh DA-100 price
This Burleigh DA-100 is listed at $779. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Burleigh DA-100 calibration cost
NIST-traceable calibration for the Burleigh DA-100 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →