Contec DIO-1616T-LPE Non-Isolated Digital I/O Board

The Contec DIO-1616T-LPE is a non-isolated digital I/O board designed for a wide range of industrial applications. It features 16 digital inputs and 16 digital outputs, providing versatile connectivity for various devices and sensors. The board is compatible with LPE bus systems, ensuring reliable data transfer and system integration.

Model
Contec DIO-1616T-LPE
Calibration
Available on request
Price
$225
Status
In stock
RFQ ref
DIO-1616T-LPE
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Contec DIO-1616T-LPE is a non-isolated digital I/O board for PCI Express systems, delivering 16 TTL-level inputs and 16 open-collector outputs in a low-profile form factor. Maximum input response time is 200nsec, with configurable per-bit interrupt control and integrated digital filtering to suppress noise and contact bounce across all input channels.

Technical Specifications

I/O Channels: 16-channel unisolated TTL-level input; 16-channel unisolated open-collector output

Input Response Time: 200nsec maximum

Output Rating: 30VDC, 40mA per signal

Input Resistance: 10kΩ (1 TTL load)

Interrupt Capability: Per-bit enable/disable, edge selection, 16 input signals consolidated to single INTA output

Digital Filter: Software-configurable, applied per input channel to eliminate noise and chatter

Connector Type: Miniature ribbon 50-pin (3M 10250-52A2JL; compatible with 10150-6000EL)

Form Factor: Low-profile PCI Express card, 121.69mm (L) × 67.90mm (H)

Bus Interface: PCI Express Base Specification Rev. 1.0a x1

Slot Compatibility: Both low-profile and standard-size slots via interchangeable bracket

Key Features

All 16 input signals can be configured as interrupt events with individual edge selection

Digital filter mitigates false triggering from noise and mechanical chatter

Open-collector outputs rated to 30VDC and 40mA per line for direct industrial load switching

TTL input format with 10kΩ input impedance

Fast 200nsec input response for time-critical applications

Typical Applications Industrial control systems, process automation, machinery integration, and real-time digital signal acquisition requiring low-latency I/O operations.

Compatibility & Integration Bundled with API-PAC(W32) function library supporting Visual Basic and Visual C++. Windows and Linux drivers included. VI-DAQ library enables LabVIEW integration. Diagnostic software provided for hardware verification. Functional and connector compatibility with legacy PIO-16/16T(LPCI)H PCI cards simplifies system migrations.

Specifications

ParameterValue
Voltage / Current Range30VDC, 40mA per signal

Contec DIO-1616T-LPE — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Contec DIO-1616T-LPE. Calibration covers per-channel threshold accuracy, input leakage current, logic level high/low margins, and signal timing verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Contec DIO-1616T-LPE faults: ESD-damaged input protection, failed driver ICs, connector pin damage. Most failures involve ESD-damaged input protection circuitry, failed logic driver ICs, or mechanical connector pin damage. Board-level component replacement is standard practice.

Contec DIO-1616T-LPE price

This Contec DIO-1616T-LPE is listed at $225. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Contec DIO-1616T-LPE calibration cost

NIST-traceable calibration for the Contec DIO-1616T-LPE is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers per-channel threshold accuracy, input leakage current, logic level high/low margins, and signal timing verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents