Eaton / Cutler-Hammer DN50SR14 D50 Programmable Controller

The Eaton/Cutler-Hammer DN50SR14 is a D50 programmable logic controller (PLC) designed for industrial automation applications. It provides reliable and efficient control for a variety of machines and processes. This PLC features a solid design and advanced functionality to meet the demands of modern automation systems.

Model
Eaton / Cutler-Hammer DN50SR14
Calibration
Available on request
Price
$325
Status
In stock
RFQ ref
DN50SR14
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Eaton/Cutler-Hammer DN50SR14 is a compact D50 series programmable logic controller engineered for small-scale industrial automation and process control. This micro PLC delivers high-speed processing of user control programs with programmable capacity up to 2000 control steps. The modular architecture supports expansion I/O modules - both digital and analog - enabling configurations from 1 to 56 control points depending on application demands.

Technical Specifications

Program Memory: 2000 control steps maximum

Control Points: 1 to 56 points (configurable)

Digital I/O: Up to 8 digital inputs; up to 6 digital outputs

Analog I/O: Up to 8 analog inputs; up to 8 analog outputs

Expansion Capability: Supports digital and analog modules for flexible I/O configuration

Communication: RS-485 ports at 9600 to 28.8K baud

Power Input: 115/230 VAC, 47 to 63 Hz, 0.6 A maximum

Physical: Compact design, 0.85 lbs

Key Features

High-speed program execution for time-critical control logic

Startup self-diagnostics and error-checking

Dual LED status indicators: Green (RUN), Red (Error)

RUN/PROG mode selector switch

EEPROM for permanent data retention

Modular construction for simplified maintenance and field repair

Typical Applications The DN50SR14 suits small-footprint control applications including machine sequencing, process monitoring, equipment interlocking, and distributed automation where space constraints or standalone operation is required.

Compatibility & Integration The D50 series design enables seamless integration with Eaton/Cutler-Hammer expansion modules. System configuration flexibility accommodates both digital and analog I/O requirements without requiring a larger controller footprint. Installation environments must be free from corrosive gases, dust, and dirt for reliable operation.

Specifications

ParameterValue
Frequency Range47 to 63 Hz | Voltage / Current Range: 0.6 A maximum, 115/230 Vac

Eaton / Cutler-Hammer DN50SR14 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Eaton / Cutler-Hammer DN50SR14. Calibration covers I/O channel accuracy per specification, analog output and input calibration to rated accuracy, and functional communication interface test (serial, Ethernet, fieldbus). All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Eaton / Cutler-Hammer DN50SR14 faults: blown I/O fuses, failed analog modules, power supply capacitor failure. Common faults include blown I/O protection fuses, failed analog I/O modules, power supply capacitor failure, and serial or Ethernet communication port damage.

Eaton / Cutler-Hammer DN50SR14 price

This Eaton / Cutler-Hammer DN50SR14 is listed at $325. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Eaton / Cutler-Hammer DN50SR14 calibration cost

NIST-traceable calibration for the Eaton / Cutler-Hammer DN50SR14 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers I/O channel accuracy per specification, analog output and input calibration to rated accuracy, and functional communication interface test (serial, Ethernet, fieldbus). Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents