Agilent / Keysight DSO9064A Oscilloscope: 600 MHz, 4 Analog Channels

Agilent / Keysight Digital Oscilloscopes. Bandwidth: 600 MHz, Sample Rate: 10 GSa/s (simultaneous all channels), Resolution: 8 bits (12 bits with high-resolution mode).

Model
Agilent / Keysight DSO9064A
Calibration
Available on request
Price
$2,410
Status
In stock
RFQ ref
DSO9064A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Agilent/Keysight DSO9064A is a 600 MHz digital phosphor oscilloscope built for signal characterization and system validation in complex test environments. Four analog channels deliver simultaneous 10 GSa/s sampling across 128 Mpts of memory, enabling deep capture of transient events and signal dynamics. The 10.4-inch XGA display combined with MegaZoom IV technology and 250,000 waveforms/second capture rate supports real-time debugging of analog and digital circuits.


Advanced triggering - including edge, glitch, pattern, video, logic, and pulse-width modes - isolates specific signal behavior with <0.5 ns RMS trigger jitter. Over 50 automatic measurements and optional serial protocol analysis (I2C, SPI, UART, USB, Ethernet, CAN, LIN, FlexRay) enable rapid characterization of embedded systems, power supplies, and communication links. The vertical system spans 1 mV/div to 5 V/div sensitivity with ±1.5% DC gain accuracy and dual-impedance inputs (1 MΩ or 50 Ω).


Timebase extends 500 ps/div to 1000 s/div with ±10 ppm accuracy, supporting precision timing analysis across analog and mixed-signal designs.


Technical Specifications



  • Bandwidth: 600 MHz

  • Analog Channels: 4

  • Maximum Sample Rate: 10 GSa/s (simultaneous all channels)

  • Memory Depth: 128 Mpts (standard, upgradeable)

  • Waveform Capture Rate: 250,000 wfms/sec (MegaZoom IV)

  • Display: 10.4-inch XGA color

  • Vertical Resolution: 8 bits (12 bits with high-resolution mode)

  • Vertical Sensitivity: 1 mV/div to 5 V/div

  • DC Gain Accuracy: ±1.5%

  • Offset Range: ±5 V (1–20 mV/div), ±50 V (50 mV/div–5 V/div)

  • Input Impedance: 1 MΩ ±2% || 12 pF ±1 pF, or 50 Ω ±2%

  • Input Coupling: AC, DC, Ground

  • Timebase Range: 500 ps/div to 1000 s/div

  • Timebase Accuracy: ±10 ppm

  • Sample Rate Accuracy: ±1 ppm

  • Trigger Jitter: <0.5 ns RMS


Key Features



  • Edge, glitch, pattern, video, logic, pulse-width, rise/fall-time, setup/hold, sequence, and parallel/serial bus triggering

  • 50+ automatic measurements: amplitude, rise/fall time, frequency, period, pulse width, duty cycle, mean, RMS, noise, overshoot, preshoot

  • Waveform math: add, subtract, multiply, divide, FFT

  • Optional jitter, eye diagram, serial protocol, power supply, and time interval analysis


Typical Applications



  • Mixed-signal circuit debugging and validation

  • Embedded system characterization (I2C, SPI, UART, USB, Ethernet, CAN, LIN, FlexRay)

  • Power supply and signal integrity analysis

  • Timing and edge-rate measurement in digital designs


Compatibility & Integration



  • USB 2.0 host and device ports

  • LAN (10/100/1000 Ethernet)

  • GPIB (IEEE 488.2)

  • External trigger input (BNC)

  • Probe compensation output (1 kHz square wave)

Agilent / Keysight DSO9064A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight DSO9064A. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Agilent / Keysight DSO9064A price

This Agilent / Keysight DSO9064A is listed at $2,410. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Agilent / Keysight DSO9064A calibration cost

NIST-traceable calibration for the Agilent / Keysight DSO9064A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →