Repair and Service Evaluation - HP/Agilent E4407A,E4407B,E4408B,E4411A,E4411B,E4440A,E4443A
Repair evaluation service for HP/Agilent E4407A, E4407B, E4408B, E4411A, E4411B, E4440A, and E4443A spectrum analyzers. This service provides a comprehensive assessment of the instrument's condition to determine the necessary repairs and associated costs.
- Model
- Agilent E4407A/E4407B/E4408B/E4411A/E4411B/E4440A/E4443A
- Calibration
- Available on request
- Price
- $100
- RFQ ref
- E4407A/E4407B/E4408B/E4411A/E4411B/E4440A/E4443A
This unit
Repair and Service Evaluation for HP/Agilent E4407A, E4407B, E4408B, E4411A, E4411B, E4440A, and E4443A spectrum analyzers. This service offering covers diagnostics, repair, calibration, and performance validation of these RF and microwave signal analysis instruments across their operational range.
Technical Specifications
These spectrum analyzers span frequency coverage from 9 kHz to 26.5 GHz, with external mixer capability extending to 325 GHz on select models. Resolution bandwidth (RBW) ranges from 1 Hz or 10 Hz to 5 MHz or 8 MHz. Video bandwidth (VBW) spans 30 Hz to 3 MHz. Amplitude accuracy varies by model: ±0.4 dB to ±1.1 dB, with premium models offering ±0.19 dB to ±0.24 dB absolute accuracy. Displayed Average Noise Level (DANL) reaches -155 dBm baseline, with optional preamplifiers enabling -167 dBm to -168 dBm performance. Third Order Intercept (TOI) is typically +16 dBm or higher. Phase noise specification on higher-end models is -118 dBc/Hz at 10 kHz offset. Sweep times are as fast as 1 ms (zero span) or 4 ms for RF sweep. Warm-up time to guaranteed accuracy is 5 minutes.Key Features
- E4407A/B: 26.5 GHz maximum, 10 MHz analysis bandwidth, optional 1 Hz narrow RBW, 1 ms sweep time, Power Suite one-button measurements
- E4408B: 26.5 GHz coverage, 4 ms RF sweep, ±1.1 dB amplitude accuracy, fully synthesized design, automatic background alignment, portable rugged construction
- E4411A/B: Portable design, 9 kHz to 1.5 GHz (E4411A) or up to 3 GHz (E4411B), 5 ms sweep time, rapid display update, field-rugged engineering, optional 75 Ohm input and tracking generator
- E4440A: 26.5 GHz maximum, 10 MHz analysis bandwidth with 40 MHz or 80 MHz options, optimized phase noise performance
Typical Applications Signal characterization, RF component testing, transmitter evaluation, interference analysis, and general-purpose microwave measurements.
Compatibility & Integration Common interfaces include GPIB, LAN, USB, RS-232, and parallel connections. High-resolution LCD and color LCD displays are standard across the series.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 9 kHz to 26.5 GHz (standard models) |
| up to 325 GHz with external mixers | Power Range (dBm) | '-155 dBm to -168 dBm (DANL) |
Agilent E4407A/E4407B/E4408B/E4411A/E4411B/E4440A/E4443A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Agilent E4407A/E4407B/E4408B/E4411A/E4411B/E4440A/E4443A. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Agilent E4407A/E4407B/E4408B/E4411A/E4411B/E4440A/E4443A price
This Agilent E4407A/E4407B/E4408B/E4411A/E4411B/E4440A/E4443A is listed at $100. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Agilent E4407A/E4407B/E4408B/E4411A/E4411B/E4440A/E4443A calibration cost
NIST-traceable calibration for the Agilent E4407A/E4407B/E4408B/E4411A/E4411B/E4440A/E4443A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →