This unit
The Ault Korea / Power General FLU3-40-1 is a 40 W open-frame switching power supply delivering triple regulated DC outputs for embedded systems and industrial electronics. It accepts universal AC input (85–265 VAC, 47–440 Hz) or DC input (100–370 VDC), with MOV-protected mains and on-board fusing. The unIt has +5 VDC @ 5 A, +12 VDC @ 3 A, and −12 VDC @ 0.7 A outputs, meeting continuous 40 W power delivery at typical efficiency of 62–75%. Protection includes power-limit overcurrent control, continuous short-circuit protection, and primary-output over-voltage clamping. Hold-up time exceeds 16 ms (115 VAC input) and 32 ms (230 VAC input) at full load. The design incorporates standard EMI filtering compliant with EN55022/FCC Class B conducted emissions. With 1% peak-to-peak ripple and noise, ±0.05°C/°C temperature coefficient, and 200,000 hour MTBF (MIL-HDBK-217F, ground benign, +25°C), the FLU3-40-1 suits OEM integration where compact form factor and multi-voltage rails are required.
Technical Specifications
Input: 85–265 VAC, 47–440 Hz or 100–370 VDC
Output Power: 40 W maximum
Output Voltages: +5 VDC @ 5 A, +12 VDC @ 3 A, −12 VDC @ 0.7 A
Efficiency: 62–75% typical
Hold-Up Time: 16 ms (115 VAC), 32 ms (230 VAC) at full load
Ripple & Noise: 1% peak-to-peak maximum
Temperature Coefficient: ±0.05%/°C
MTBF: 200,000 hours (MIL-HDBK-217F, ground benign, TA = +25°C)
Input Fuse: 2 A/250 V slow-blow (recommended replacement)
Key Features
Triple regulated outputs for mixed-voltage applications
Universal AC and DC input acceptance
Continuous short-circuit and overcurrent protection
MOV transient suppression on mains input
EMI filtering meets EN55022/FCC Class B
Low ripple specification (1% peak-to-peak)
16–32 ms hold-up time across input range
Typical Applications
Industrial control and instrumentation
Embedded system power distribution
Multi-rail OEM integration
Telecom and network equipment
Compatibility & Integration Open-frame configuration suits direct PCB mounting and confined enclosures. On-board fusing and transient protection reduce external component count. Outputs support standard load-share and voltage-sequencing topologies common in legacy and modern embedded designs.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 47–440 Hz | Voltage / Current Range: '+12 VDC @ 3 A, −12 VDC @ 0.7 A output, 85–265 VAC or 100–370 VDC input |
Ault Korea / Power General FLU3-40-1 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Ault Korea / Power General FLU3-40-1. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Ault Korea / Power General FLU3-40-1 price
This Ault Korea / Power General FLU3-40-1 is listed at $125. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Ault Korea / Power General FLU3-40-1 calibration cost
NIST-traceable calibration for the Ault Korea / Power General FLU3-40-1 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →