Exfo FVA-80-B50-C22-IE Singlemode and Multimode Variable Attenuator

Exfo Optical Attenuators. Resolution: 0.01 dB.

Model
Exfo FVA-80-B50-C22-IE
Calibration
Available on request
Price
$1,650
Status
In stock
RFQ ref
FVA-80-B50-C22-IE
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Exfo FVA-80-B50-C22-IE is a dual-channel variable optical attenuator integrating singlemode and multimode functionality within a single portable unit. Each channel operates independently with dedicated optical interfaces, enabling precise attenuation control across multiple wavelengths and fiber types. The instrument delivers up to 65 dB maximum attenuation with 0.01 dB optical resolution and insertion loss below 3.0 dB, making it suitable for R&D, production testing, and field deployment.

Technical Specifications

Attenuation Range: 0 to 65 dB maximum

Optical Resolution: 0.01 dB

Insertion Loss: < 3.0 dB

Singlemode Wavelengths: 1300 nm, 1550 nm (additional calibration wavelengths available)

Multimode Wavelengths: 850 nm, 1300 nm (additional calibration wavelengths available)

Return Loss: High performance design (specific values not documented)

Optical Shutter: Attenuation exceeding 100 dB when activated

Programmable Steps: Up to 60 attenuation values with user-defined step size

Step Timing: Intervals up to 23 hours, 59 minutes, 59 seconds

Key Features

Dual independent singlemode/multimode channels in single housing

Manual mode for direct attenuation control

Program mode supporting automated test sequences

Relative attenuation display modes with "X + B" reference configuration

Step/Scan modes for dynamic attenuation adjustment

Optical shutter with remote BNC control

Rechargeable internal battery for field portability

RS-232 and IEEE-488 remote interfaces

Typical Applications

Optical communication system testing and optimization

Automated attenuator sequences in production environments

Reference loss simulation and system characterization

Field and laboratory measurements

Compatibility & Integration Remote operation via RS-232 and IEEE-488 interfaces supports integration into automated test systems. External shutter control available through rear-panel BNC connector.

Specifications

ParameterValue
Wavelength Range1300 nm, 1550 nm, 850 nm

Exfo FVA-80-B50-C22-IE — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Exfo FVA-80-B50-C22-IE. Calibration covers attenuation accuracy at 5 or more set values across the full range (0 to rated maximum dB), attenuation linearity, wavelength-dependent attenuation at 1310 nm, 1490 nm, and 1550 nm, insertion loss at minimum attenuation (0 dB position), and polarization-dependent loss (PDL) where applicable. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Exfo FVA-80-B50-C22-IE faults: motor and gear mechanism wear (attenuation steps or loss of smooth control), optical port contamination, EEPROM calibration data corruption. Most common faults are motor or gear mechanism wear on variable attenuators causing attenuation steps or loss of smooth control, optical port contamination reducing dynamic range, and EEPROM calibration data corruption on digitally controlled models.

Exfo FVA-80-B50-C22-IE price

This Exfo FVA-80-B50-C22-IE is listed at $1,650. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Exfo FVA-80-B50-C22-IE calibration cost

NIST-traceable calibration for the Exfo FVA-80-B50-C22-IE is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers attenuation accuracy at 5 or more set values across the full range (0 to rated maximum dB), attenuation linearity, wavelength-dependent attenuation at 1310 nm, 1490 nm, and 1550 nm, insertion loss at minimum attenuation (0 dB position), and polarization-dependent loss (PDL) where applicable. Turnaround is 1 to 3 business days after receipt. See full calibration details →