JDS Uniphase HA9 JDSU HA97+18KFA1 Programmable Attenuator
JDS Uniphase/JDSU Optical Attenuators. Resolution: 0.01 dB, Accuracy: ±0.03 dB typical.
- Model
- JDS Uniphase/JDSU HA97+18KFA1
- Calibration
- Available on request
- Price
- $2,930
- Status
- In stock
- RFQ ref
- HA97+18KFA1
This unit
The JDS Uniphase HA97+18KFA1 is a programmable optical attenuator designed for precise control of optical signal levels in fiber optic networks. It delivers 100 dB of attenuation with 0.01 dB resolution and ±0.03 dB typical accuracy, making it suitable for demanding test and measurement applications across the C- and L-bands. The instrument supports both automated and manual adjustment via GPIB and RS232 interfaces, with command compatibility to the HP8156A standard.
Technical Specifications
- Attenuation Range: 100 dB
- Attenuation Resolution: 0.01 dB
- Attenuation Accuracy: ±0.03 dB typical
- Wavelength Range: 1200–1700 nm
- Insertion Loss: 2.5 dB (including connectors)
- Return Loss: 60 dB (analog)
- Repeatability: 0.01 dB
- Polarization Dependent Loss (PDL): 0.03 dB typical
- Wavelength Dependence: <±0.05 dB over 1530–1625 nm
- Maximum Optical Input Power: 1000 mW (1 W / 30 dBm) for HA2 models
- Fiber Type: Single-mode 9/125 µm; multimode configurable
- Connector Type: SC/PC; FC/APC available for specific configurations
- Control Interfaces: GPIB (IEEE 488.2), RS232
- Command Set: SCPI/HP8156A compatible
Key Features
- 0.01 dB resolution enables fine-grained power control in laboratory and field environments
- Wide dynamic range supports loss simulation and power conditioning across extended wavelength spans
- Bulkhead front-panel ports simplify integration into test racks and systems
- Optional integrated switching and coupler configurations (1×2 switch, beam block, 2/98, 10/90, 30/70, 50/50 couplers)
- Universal Connector Adapters (UCAs) available for diverse deployment scenarios
Typical Applications
- Power meter linearity calibration
- BER testing in analog and digital transmission systems
- EDFA output power characterization and amplifier testing
- DWDM system validation and loss simulation in fiber links
- Multichannel AM systems and high bit-rate PCM systems
Compatibility & Integration Certifications: CE, UL3101-1, CAN/CSA-C22.2 No. 1010.1. Remote control via standard GPIB and RS232 enables integration into automated test benches and network maintenance workflows.
Specifications
| Parameter | Value |
|---|---|
| Power Range (dBm) | 30 dBm (1000 mW maximum optical input) | Wavelength Range: 1200–1700 nm |
JDS Uniphase/JDSU HA97+18KFA1 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the JDS Uniphase/JDSU HA97+18KFA1. Calibration covers attenuation accuracy at 5 or more set values across the full range (0 to rated maximum dB), attenuation linearity, wavelength-dependent attenuation at 1310 nm, 1490 nm, and 1550 nm, insertion loss at minimum attenuation (0 dB position), and polarization-dependent loss (PDL) where applicable. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common JDS Uniphase/JDSU HA97+18KFA1 faults: motor and gear mechanism wear (attenuation steps or loss of smooth control), optical port contamination, EEPROM calibration data corruption. Most common faults are motor or gear mechanism wear on variable attenuators causing attenuation steps or loss of smooth control, optical port contamination reducing dynamic range, and EEPROM calibration data corruption on digitally controlled models.
JDS Uniphase/JDSU HA97+18KFA1 price
This JDS Uniphase/JDSU HA97+18KFA1 is listed at $2,930. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
JDS Uniphase/JDSU HA97+18KFA1 calibration cost
NIST-traceable calibration for the JDS Uniphase/JDSU HA97+18KFA1 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers attenuation accuracy at 5 or more set values across the full range (0 to rated maximum dB), attenuation linearity, wavelength-dependent attenuation at 1310 nm, 1490 nm, and 1550 nm, insertion loss at minimum attenuation (0 dB position), and polarization-dependent loss (PDL) where applicable. Turnaround is 1 to 3 business days after receipt. See full calibration details →