This unit

The JDS Uniphase HA9 (JDSU HA097+29KFP1) is a programmable optical attenuator delivering precise, dynamic control of optical signal strength across broad wavelength ranges. Purpose-built for optical communication system testing, measurement, and calibration, It has attenuation up to 100 dB with 0.01 dB resolution and typical accuracy of ±0.03 dB.


Technical Specifications

Attenuation Performance

  • Range: Up to 100 dB

  • Resolution: 0.01 dB

  • Accuracy (typical): ±0.03 dB

  • Accuracy (specified): ±0.1 dB

  • Insertion loss (typical, including connectors): 2.5 dB

  • Insertion loss (minimum): 2.328 dB at 1550 nm

  • Return loss: Better than 60 dB Wavelength Coverage

  • Standard range: 1200 nm to 1700 nm

  • Extended range (HA9W option): 750 nm to 1700 nm (with 60 dB maximum attenuation) Optical Interface

  • Fiber type: Single-mode 9/125 µm

  • Connectors: SC/PC, SC/APC, FC/PC; optional front or back panel universal connector adapters

  • Port mounting: Front panel bulkheads Control & Integration

  • Front panel keyboard control

  • GPIB (IEEE 488.2) interface

  • RS232 interface

  • Command set: SCPI / HP8156A compatible


Key Features



  • High input power capability: 200 mW maximum

  • Built-in 1×2 optical switch

  • Integrated optical couplers: 2/98, 10/90, 30/70, 50/50 ratios

  • Beam blocking switch for fast access to >90 dB attenuation

  • Class 1 instrument with exposed metal chassis and earth ground connection


Typical Applications



  • Power meter testing and calibration

  • Bit error rate (BER) testing

  • Amplifier characterization

  • DWDM system validation

  • Multi-channel AM system analysis

  • High bit-rate PCM system evaluation


Compatibility & Integration The HA9 integrates with test benches via GPIB and RS232 interfaces. HP8156A command compatibility simplifies integration into existing measurement systems. Standard and extended wavelength options accommodate diverse fiber-optic applications from visible through C and L bands.

Specifications

ParameterValue
Wavelength Range1200 nm to 1700 nm (standard)

JDS Uniphase/JDSU HA9/HA097+29KFP1 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the JDS Uniphase/JDSU HA9/HA097+29KFP1. Calibration covers attenuation accuracy at 5 or more set values across the full range (0 to rated maximum dB), attenuation linearity, wavelength-dependent attenuation at 1310 nm, 1490 nm, and 1550 nm, insertion loss at minimum attenuation (0 dB position), and polarization-dependent loss (PDL) where applicable. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common JDS Uniphase/JDSU HA9/HA097+29KFP1 faults: motor and gear mechanism wear (attenuation steps or loss of smooth control), optical port contamination, EEPROM calibration data corruption. Most common faults are motor or gear mechanism wear on variable attenuators causing attenuation steps or loss of smooth control, optical port contamination reducing dynamic range, and EEPROM calibration data corruption on digitally controlled models.

JDS Uniphase/JDSU HA9/HA097+29KFP1 price

This JDS Uniphase/JDSU HA9/HA097+29KFP1 is listed at $2,930. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

JDS Uniphase/JDSU HA9/HA097+29KFP1 calibration cost

NIST-traceable calibration for the JDS Uniphase/JDSU HA9/HA097+29KFP1 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers attenuation accuracy at 5 or more set values across the full range (0 to rated maximum dB), attenuation linearity, wavelength-dependent attenuation at 1310 nm, 1490 nm, and 1550 nm, insertion loss at minimum attenuation (0 dB position), and polarization-dependent loss (PDL) where applicable. Turnaround is 1 to 3 business days after receipt. See full calibration details →