JDS Uniphase HA9 - HA91C+10KFP1
JDS Uniphase Optical Attenuators. Resolution: ** 0.01 dB (nominal), Accuracy: ** ±0.1 dB.
- Model
- JDS Uniphase HA9-HA91C+10KFP1
- Calibration
- Available on request
- Price
- $1,750
- Status
- In stock
- RFQ ref
- HA9-HA91C+10KFP1
This unit
The JDS Uniphase HA9-HA91C+10KFP1 is a programmable optical attenuator engineered for precise attenuation of optical signals in laboratory and field testing environments. This instrument delivers 100 dB attenuation range with 0.01 dB resolution and repeatability, supporting input power up to 1000 mW (30 dBm) across single-mode and multimode fiber. It excels in power meter calibration, link loss simulation, bit error rate testing, and DWDM system characterization.
Technical Specifications
Attenuation Range: 100 dB
Resolution: 0.01 dB (nominal)
Repeatability: 0.01 dB
Accuracy: ±0.1 dB
Wavelength Range: 1200–1700 nm (standard); 750–1700 nm available (HA9W variant with 60 dB reduced range)
Wavelength Dependence: ±0.05 dB across 1530–1625 nm
Polarization Dependent Loss (PDL): ≤0.03 dB (typical)
Return Loss: >60 dB (internal reflections minimized)
Input Power: Up to 1000 mW (30 dBm)
Fiber Compatibility: Single-mode and multimode (50/125 µm)
Key Features
Fiber type selection via front panel keyboard, GPIB, or RS232
SCPI/HP8156A command compatibility
Optional 1:2 optical fiber switch (SW12) for dual input/output selection
Interchangeable couplers: 2/98, 10/90, 30/70, or 50/50 configurations
5V driver output for external/internal switch control
Class 1 safety classification
Typical Applications
Power meter linearity calibration
Analog transmission and bit error rate testing
Fiber optic link loss simulation
EDFA output power characterization
DWDM system analysis
Multi-channel AM and high bit-rate PCM systems
Compatibility & Integration The HA91C+10KFP1 accepts optional built-in couplers and switches, enabling modular configuration for specific test setups. External devices integrate via front panel access. Standard interfaces support lab automation and remote instrument control.
Specifications
| Parameter | Value |
|---|---|
| Power Range (dBm) | Up to 30 dBm input | Voltage / Current Range: '+5V output | Wavelength Range: 1200–1700 nm (standard) |
JDS Uniphase HA9-HA91C+10KFP1 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the JDS Uniphase HA9-HA91C+10KFP1. Calibration covers attenuation accuracy at 5 or more set values across the full range (0 to rated maximum dB), attenuation linearity, wavelength-dependent attenuation at 1310 nm, 1490 nm, and 1550 nm, insertion loss at minimum attenuation (0 dB position), and polarization-dependent loss (PDL) where applicable. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common JDS Uniphase HA9-HA91C+10KFP1 faults: motor and gear mechanism wear (attenuation steps or loss of smooth control), optical port contamination, EEPROM calibration data corruption. Most common faults are motor or gear mechanism wear on variable attenuators causing attenuation steps or loss of smooth control, optical port contamination reducing dynamic range, and EEPROM calibration data corruption on digitally controlled models.
JDS Uniphase HA9-HA91C+10KFP1 price
This JDS Uniphase HA9-HA91C+10KFP1 is listed at $1,750. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
JDS Uniphase HA9-HA91C+10KFP1 calibration cost
NIST-traceable calibration for the JDS Uniphase HA9-HA91C+10KFP1 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers attenuation accuracy at 5 or more set values across the full range (0 to rated maximum dB), attenuation linearity, wavelength-dependent attenuation at 1310 nm, 1490 nm, and 1550 nm, insertion loss at minimum attenuation (0 dB position), and polarization-dependent loss (PDL) where applicable. Turnaround is 1 to 3 business days after receipt. See full calibration details →