LeCroy HVD3206 High Voltage Differential Probe, 120MHz

Lecroy Laboratory Measurement Instruments. Bandwidth: 120 MHz, Voltage: Up to 1500 Vdc, Accuracy: 1%.

Model
Lecroy HVD3206
Calibration
Available on request
Price
$2,229
Status
In stock
RFQ ref
HVD3206
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The LeCroy HVD3206 is a high-voltage differential probe engineered for precision measurements in power electronics, solar photovoltaic systems, and high-voltage industrial applications. Operating at 120 MHz bandwidth with DC input coupling, it delivers 1% gain accuracy and exceptional common-mode rejection across a broad frequency range. The probe accommodates differential voltages up to 2000 V (DC + peak AC) at high attenuation and manages common-mode voltages up to 1500 Vdc, making it ideally suited for 1500 Vdc solar PV measurements per IEC/EN 61010-031:2015.


Its 2 kV CAT I and 1500 Vdc CAT III safety ratings ensure compliance in demanding test environments.


Technical Specifications



  • Bandwidth: 120 MHz

  • Input Coupling: DC

  • Safety Rating: 2 kV CAT I, 1500 Vdc CAT III

  • Differential Voltage Range (High Attenuation): 2000 V (DC + peak AC) from 7 to 500 V/div with up to 1500 V offset

  • Differential Voltage Range (Low Attenuation): 27.6 V (DC + peak AC) from 100 mV/div to 6.9 V/div with up to 150 V offset

  • Common-Mode Voltage: Up to 1500 Vdc

  • Gain Accuracy: 1%

  • Input Impedance: 10 MΩ || 2.5 pF (between inputs); 5 MΩ || 5.0 pF (input to ground)

  • Common-Mode Rejection Ratio: Exceptional across broad frequency range


Key Features



  • ProBus active probe interface provides integrated power and oscilloscope communication without separate power supply or batteries

  • Automatic attenuation selection synchronized with oscilloscope gain range (V/div)

  • AutoZero functionality calibrates small offset drifts while probe remains connected to device under test

  • High offset capability at both attenuation settings

  • Standard 2 meter cable with optional 6 meter variant (HVD3206A-6M)


Typical Applications



  • Switch-mode power supplies

  • 600 V and 5 kV class electrical apparatus

  • High-power DC-DC converters

  • Solar photovoltaic systems


Compatibility & Integration Designed for broad oscilloscope compatibility via ProBus interface. Supplied with 2 kV plunger alligator clips, soft carrying case with foam insert, and user manual.

Specifications

ParameterValue
Frequency RangeDC to 120 MHz | Voltage / Current Range: 27.6 V to 2000 V differential (depending on attenuation)

Lecroy HVD3206 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Lecroy HVD3206. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Lecroy HVD3206 price

This Lecroy HVD3206 is listed at $2,229. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Lecroy HVD3206 calibration cost

NIST-traceable calibration for the Lecroy HVD3206 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents