GE Fanuc / ICS ICS-1555A-005 4-Channel, 160/180 MHz 16-bit ADC PMC Module with Virtex-5 SX95T User Programmable FPGA
GE Fanuc / ICS Data Acquisition Systems (DAQ). Voltage: 1.48 dBm (0.75 Vpp) or 5 dBm (1.125 Vpp), Bandwidth: 2 MHz to 300 MHz (-3 dB), Sample rate: 160 MHz or 180 MHz per channel.
- Model
- GE Fanuc / ICS ICS-1555A-005
- Calibration
- Available on request
- Price
- $2,400
- Status
- In stock
- RFQ ref
- ICS-1555A-005
This unit
The GE Fanuc / ICS ICS-1555A-005 is a 4-channel, 16-bit analog-to-digital converter (ADC) PMC module built around a user-programmable Xilinx Virtex-5 SX95T FPGA. It delivers simultaneous sampling at 160 MHz or 180 MHz per channel with AC-coupled 50 Ω inputs spanning 2 MHz to 300 MHz (-3 dB). The module integrates four Graychip GC4016 digital down-converters for flexible multi-band signal extraction and narrows signals to 10 MHz (-1 dB) per channel. Its PCI-X interface supports 64-bit/133 MHz master/target operation with burst-mode DMA, while 64 user I/Os connect directly to the FPGA via the Pn4 connector. Signal integrity is maintained with S/(N+D) ratios exceeding 73 dBFs at 160 MSPS and 70 dBFs at 180 MSPS, plus spurious-free dynamic range of 84 dBc at 70 MHz. Extended temperature variants are available.
Technical Specifications Analog Inputs
4 channels, AC-coupled, 50 Ω input impedance
Full-scale voltage: 1.48 dBm (0.75 Vpp) or 5 dBm (1.125 Vpp), software selectable
Input bandwidth: 2 MHz to 300 MHz (-3 dB)
Sample rate: 160 MHz or 180 MHz per channel; minimum 1 MHz
Resolution: 16-bits Sampling Clock
Internal: 100 MHz (Silicon Labs Si571)
External: 32 MHz to 180 MHz, LVTTL/sinewave compatible
External trigger: LVTTL/LVCMOS with 5V tolerance, edge-selectable
External sync: LVTTL/sinewave, -3 dB min. to +6 dBm max. Digital Down-Converters
4× Graychip GC4016 devices
Simultaneous down-conversion of up to 16 arbitrary signal bands
Configuration: up to 16 narrowband, 8 split-I/Q, or 4 wideband channels
Maximum output bandwidth: 10 MHz (-1 dB) per channel
Arbitrary center frequency tuning within passband FPGA
Xilinx Virtex-5 SX95T, user-programmable
36-Kbit block RAM/FIFOs, 25×18 DSP slices, SelectIO technology
ChipSync interface blocks, system monitor, enhanced clock management with DCMs and PLLs Interfaces
PCI-X: 64-bit/133 MHz, master/target, burst-mode DMA capable (PCI Local Bus Specification Revision 3.0, CMC/PMC P1386.1)
User I/O: 64 lines via Pn4 connector (LVDS or LVTTL) Performance
S/(N+D): >73 dBFs @ 70 MHz input, 160 MSPS; >70 dBFs @ 90 MHz input, 180 MSPS
SFDR: 84 dBc @ 70 MHz input
Key Features
Multi-band signal extraction with four integrated digital down-converters
Programmable FPGA for custom signal processing and control
Flexible sampling clock (internal or external, 32–180 MHz)
High dynamic range and low spurious content
Typical Applications
Communications signal analysis
Radar data acquisition
Test and measurement
Compatibility & Integration PCI-X master/target interface with DMA capability integrates into standard CompactPCI and PMC carrier systems. Pn4 connector provides direct FPGA access for custom I/O protocols and signal routing.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 2 MHz to 300 MHz (input signal bandwidth) |
| 160 MHz or 180 MHz (sampling rate) | Power Range (dBm) | Full-scale: 1.48 dBm to 5 dBm |
| External sync | -3 dB min. to +6 dBm max. |
| SFDR | 84 dBc @ 70 MHz | Voltage / Current Range: 0.75 Vpp (1.48 dBm) to 1.125 Vpp (5 dBm) full-scale |
GE Fanuc / ICS ICS-1555A-005 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the GE Fanuc / ICS ICS-1555A-005. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
GE Fanuc / ICS ICS-1555A-005 price
This GE Fanuc / ICS ICS-1555A-005 is listed at $2,400. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
GE Fanuc / ICS ICS-1555A-005 calibration cost
NIST-traceable calibration for the GE Fanuc / ICS ICS-1555A-005 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →