LeCroy LA314H 470MHz Analog Scope, 470MHz, 4 Channel

Lecroy Digital Oscilloscopes. Sensitivity: 2 mV/div to 5 V/div, Voltage: axis.

Model
Lecroy LA314H
Calibration
Available on request
Price
$1,979
Status
In stock
RFQ ref
LA314H
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The LeCroy LA314H is a 4-channel analog oscilloscope delivering 470 MHz bandwidth for signal analysis and troubleshooting across diverse electronic applications. Its high-intensity CRT analog display renders subtle waveform details including gray scaling and persistence effects, making it particularly suited for mixed-signal analysis and low-repetition-rate event capture. The instrument combines ultrafast display update rates with a multipurpose trigger system, broad input offset capability, dual-axis cursors, and an integrated 5-digit frequency counter.


Technical Specifications

Bandwidth & Channels

  • 470 MHz (-3 dB) at 5 mV/div to 50 mV/div vertical settings

  • 440 MHz at 2 mV/div, 100 mV/div to 5 V/div settings

  • 4 isolated channels Vertical System

  • Sensitivity: 2 mV/div to 5 V/div

  • DC input offset: ±500 divisions maximum (±1 V to ±50 mV/div range on CH1 or CH2)

  • Bandwidth limiter: 20 MHz and 100 MHz selectable Timebase

  • Sweep speed: 500 ps/div minimum

  • Range: 5 ns/div to 20 ms/div ±2% in 21 steps (1, 2, 5 sequence)

  • Magnifier: 10× capability Input Characteristics

  • Coupling: AC or DC

  • Hi-Z impedance: 1 MΩ ±1.5% with 16 pF ±2 pF

  • Lo-Z impedance: 50 Ω ±1%

  • Maximum input: ±400 V (1 MΩ path); 5 V RMS (50 Ω path)

  • Probe attenuation detection: 1:1, 1:10, 1:100 Triggering System

  • Sources: CH1, CH2, CH3, CH4, LINE

  • Coupling modes: AC, DC, HF-REJ, LF-REJ

  • Polarity: ± selectable

  • TV trigger: NTSC, PAL, SECAM, HDTV with field (EVEN, ODD, BOTH) and line selection

  • Event delay: Count range 1–65535 at up to 50 MHz; burst timing 0.15 µs to 9.99 s

  • Auto setup: CH1 and CH2, 50 Hz to 100 MHz range Measurement Tools

  • Frequency counter: 2 Hz to 400 MHz, ±0.01% accuracy

  • Cursors: 2 voltage-axis, 2 time-axis with simultaneous ΔT and ΔV readout

  • X-Y operation: CH1 on X-axis; CH1, CH2, CH3, CH4, or ADD on Y-axis (±2% accuracy at +10°C to +35°C)


Key Features



  • Real-time waveform observation via ultrafast CRT update rate

  • Comprehensive trigger flexibility for complex signal conditions

  • Dual-impedance input paths (1 MΩ and 50 Ω) for RF and low-impedance measurements

  • Built-in frequency counter eliminates external instrumentation

  • Persistence and gray-scale display modes for transient and statistical analysis

Specifications

ParameterValue
Frequency Range2 Hz to 400 MHz (frequency counter)
50 Hz to 100 MHz (auto setup) | Voltage / Current Range±400 V (1 MΩ input), 5 V RMS (50 Ω input)

Lecroy LA314H — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Lecroy LA314H. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Lecroy LA314H price

This Lecroy LA314H is listed at $1,979. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Lecroy LA314H calibration cost

NIST-traceable calibration for the Lecroy LA314H is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →