ILX Lightwave LDX-3210 Laser Diode Driver, Precision

The ILX Lightwave LDX-3210 is a precision laser diode driver designed for demanding laser control applications. It offers low noise and high stability, ensuring accurate and reliable performance. Ideal for laboratory and industrial settings requiring precise laser control.

Model
ILX Lightwave LDX-3210
Calibration
Available on request
Price
$930
Status
In stock
RFQ ref
LDX-3210
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The ILX Lightwave LDX-3210 is a precision laser diode current source engineered for high-stability, low-noise control in demanding laboratory and industrial environments. Part of the LDX-3200 series, this instrument combines dual-range current capability with integrated laser diode protection circuits, delivering ±0.05% set point accuracy and <10 ppm FS 1-hour stability. It supports constant current and constant power operating modes, along with analog modulation up to 1 MHz, making it suitable for both DC and dynamic applications.

Technical Specifications Current Control

Laser current ranges: 50 mA / 100 mA (dual range)

Set point accuracy: ±0.05% FS

Set point resolution: 1 µA (50 mA range), 2 µA (100 mA range)

Output current noise/ripple: 1.5 µA rms (low bandwidth), 4 µA (high bandwidth)

1-hour stability: <10 ppm FS

24-hour stability: <20 ppm FS

Transfer function: 50 mA/V Voltage & Monitoring

Laser compliance voltage: 10 V

Forward voltage accuracy: ±2.5%

Forward voltage resolution: 50 mV

Four-wire forward voltage measurement: Standard

Photodiode current accuracy: ±0.04% FS (0 to 5000 µA range)

Monitor current accuracy: ±2 µA (5 to 5000 µA range)

Photodiode reverse bias: 0 to 5 V Modulation & Performance

External modulation: DC to 1 MHz (high bandwidth), DC to 15 kHz (low bandwidth)

Temperature coefficient: <50 ppm FS/°C

Display: 5-digit green LED

Key Features

Clamping current limits with protection during modulation

Adjustable current and voltage limits

Intermittent contact protection and redundant output shorting circuits

Slow start routine prevents over-current and turn-on transients

Front-panel output-shorting switch for safe on/off control

AC power-up protection via redundant shorting circuits

Typical Applications Laser diode characterization, spectroscopy, optical communications testing, and photonics research requiring precision current sourcing with comprehensive device protection.

Compatibility & Integration

GPIB/IEEE-488 computer interface (standard)

LabVIEW instrument drivers available

Power requirements: 220 VAC (120 VAC versions available)

Specifications

ParameterValue
Frequency RangeDC to 1 MHz | Voltage / Current Range: 0-10 V compliance, 220 VAC input, 50 mA / 100 mA dual range

ILX Lightwave LDX-3210 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the ILX Lightwave LDX-3210. Calibration covers output power at specified wavelengths, wavelength accuracy, 15-minute output stability, and modulation frequency accuracy where applicable. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common ILX Lightwave LDX-3210 faults: laser diode end-of-life (output below spec), fiber output connector damage, output instability. Common repairs include laser diode replacement when output falls below spec, fiber output connector repair, and thermal management service.

ILX Lightwave LDX-3210 price

This ILX Lightwave LDX-3210 is listed at $930. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

ILX Lightwave LDX-3210 calibration cost

NIST-traceable calibration for the ILX Lightwave LDX-3210 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output power at specified wavelengths, wavelength accuracy, 15-minute output stability, and modulation frequency accuracy where applicable. Turnaround is 1 to 3 business days after receipt. See full calibration details →