Lambda / TDK / EMI LNS-W-5-OV

Lambda / TDK / EMI DC Power Supplies. Voltage: 5 V DC maximum, Current: 11.9 A DC maximum, Frequency range: 47–440 Hz supports global and variable-frequency.

Model
Lambda / TDK / EMI LNS-W-5-OV
Calibration
Available on request
Price
$340
Status
In stock
RFQ ref
LNS-W-5-OV
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Lambda/TDK/EMI LNS-W-5-OV is a linear, convection-cooled power supply delivering 63 W at 5 V DC for industrial and commercial applications requiring low-noise, stable power. This single-output unit is engineered for systems with sensitive analog circuits, offering 1.5 mV RMS ripple and 5 mV peak-to-peak noise. Overvoltage protection and automatic electronic current limiting are standard, with remote sensing capability to compensate for lead resistance effects on DC regulation.


Technical Specifications



  • Output Power: 63 W

  • Output Voltage: 5 V DC maximum

  • Output Current: 11.9 A DC maximum

  • AC Input: 105–127 VAC or 210–254 VAC (via transformer tap change)

  • Input Frequency: 47–440 Hz

  • Line Regulation: 0.1%

  • Load Regulation: 0.1%

  • Output Ripple & Noise: 1.5 mV RMS, 5 mV pk-pk

  • Operating Temperature: 0°C to +71°C (derating required above +40°C)

  • Storage Temperature: −56°C to +85°C

  • EMI Compliance: MIL-F-61810 (conducted and radiated, one output terminal grounded)


Key Features



  • Convection cooling eliminates need for external heat sinks or forced-air systems

  • Heavy-duty screw terminals on PCB for solid connections

  • Overvoltage protection standard on 5V models

  • Automatic electronic current limiting protects load and supply

  • Thermostat with automatic reset upon temperature normalization

  • Remote sensing provision for precision DC regulation

  • Wide AC input frequency range: 47–440 Hz supports global and variable-frequency sources


Typical Applications Industrial control systems, medical instrumentation, test equipment, and precision analog circuits requiring exceptionally low noise and high regulation accuracy.


Compatibility & Integration Part of the TDK-Lambda LN Series. Mounting provisions include tapped holes for customer-specified fasteners. Output connections via PCB-mounted screw terminals. Standard dimensions for LN-W series: 9" × 4.5" × 4.313" (net weight 9 lbs).

Specifications

ParameterValue
Frequency Range47–440 Hz | Voltage / Current Range: 105–127 VAC / 210–254 VAC input

Lambda / TDK / EMI LNS-W-5-OV — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Lambda / TDK / EMI LNS-W-5-OV. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Lambda / TDK / EMI LNS-W-5-OV price

This Lambda / TDK / EMI LNS-W-5-OV is listed at $340. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Lambda / TDK / EMI LNS-W-5-OV calibration cost

NIST-traceable calibration for the Lambda / TDK / EMI LNS-W-5-OV is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →