Anritsu MA2442D High Accuracy Sensor 10 MHz to 18 GHz

Anritsu MA2442D High Accuracy Sensor covers 10 MHz to 18 GHz and offers precise power measurement with fast response time. Its reliable performance supports various wireless communication testing scenarios, ensuring accurate characterization of signal power.

Model
Anritsu MA2442D
Calibration
Available on request
Price · starting from
$830
Status
In stock
RFQ ref
MA2442D
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Anritsu MA2442D is a high-accuracy diode sensor for precision power measurement across 10 MHz to 18 GHz. It delivers an 87 dB dynamic range from −67 dBm to +20 dBm in CW mode, with extended measurement capabilities in profile and pulse/modulation modes when paired with compatible Anritsu power meters. The sensor incorporates a 3 dB attenuator to minimize input VSWR, achieving performance as low as <1.08 across 150 MHz to 2 GHz and maintaining linearity within 1.8% to 18 GHz.


Rise time of <0.004 ms supports accurate TDMA and modulated signal characterization.


Technical Specifications



  • Frequency Range: 10 MHz to 18 GHz

  • CW Mode Power Range: −67 dBm to +20 dBm

  • Profile Mode Power Range: −40 dBm to +20 dBm (with ML243xA)

  • Pulse/Mod Mode Power Range: −34 dBm to +20 dBm or −37 dBm to +20 dBm (with ML2480A/B or ML2490A)

  • Dynamic Range: 87 dB

  • Sensor Linearity: 1.8% (≤18 GHz)

  • Rise Time: <0.004 ms

  • VSWR: <1.17 (10 MHz–150 MHz); <1.08 (150 MHz–2 GHz); <1.16 (2 GHz–12.4 GHz); <1.21 (12.4 GHz–18 GHz)

  • RF Connector: N-type (male)


Key Features



  • Integrated 3 dB attenuator reduces input VSWR across the measurement band

  • Calibration factors stored in on-board EEPROM for rapid meter integration

  • Supports CW, TDMA, pulse, and modulation mode measurements

  • Optimized for amplifier characterization and broadband RF power validation


Typical Applications



  • Wireless communication system validation

  • RF amplifier characterization and acceptance testing

  • Modulated signal power measurement in TDMA systems

  • Broadband power monitoring from microwave through millimeter-wave bands


Compatibility & Integration Designed for direct integration with Anritsu ML2430, ML2480, and ML2490 series power meters. Calibration data embedded in sensor EEPROM enables plug-and-play operation.

Specifications

ParameterValue
Frequency Range10 MHz to 18 GHz | Power Range (dBm): −67 dBm to +20 dBm

Anritsu MA2442D — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Anritsu MA2442D. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Anritsu MA2442D price

This Anritsu MA2442D is listed at $830. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Anritsu MA2442D calibration cost

NIST-traceable calibration for the Anritsu MA2442D is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →