Anritsu MS2760A-0090 – Spectrum Master, Ultraportable Spectrum Analyzer; 9 kHz to 90 GHz
The Anritsu MS2760A-0090 is an ultraportable spectrum analyzer that operates from 9 kHz to 90 GHz. It is part of the Spectrum Master series, designed for comprehensive spectrum analysis in a compact and lightweight form factor. Ideal for field use, it offers high performance for various applications including signal monitoring, interference analysis, and component testing.
- Model
- Anritsu MS2760A-0090
- Calibration
- Available on request
- Price
- $22,000
- RFQ ref
- MS2760A-0090
This unit
The Anritsu MS2760A-0090 is an ultraportable spectrum analyzer delivering 9 kHz to 90 GHz coverage in a pocket-sized form factor. Weighing 255 g and measuring 155 mm × 84 mm × 27 mm, it integrates Anritsu's patented Nonlinear Transmission Line (NLTL) technology to achieve dynamic range exceeding 100 dB while maintaining competitive cost-per-performance. The instrument operates via USB power and connects to Windows-based PCs, laptops, or tablets for field, manufacturing, or laboratory deployment. Direct connection to devices under test eliminates reliance on lossy cable runs, critical for high-frequency measurements.
Technical Specifications Frequency & Amplitude
Frequency range: 9 kHz to 90 GHz
Amplitude measurement: +10 dBm to −136 dBm
Amplitude accuracy: ±0.5 dB typical to 170 GHz Noise & Dynamic Range
Displayed Average Noise Level (DANL): −134 dBm (4–40 GHz), −132 dBm/Hz typical to 70 GHz, −141 dBm to 90 GHz
Dynamic range: >103 dB typical at 70 GHz; >100 dB minimum via NLTL technology Receiver Metrics
Resolution bandwidth: 1 Hz to 3 MHz
Third-order intercept (TOI): +35 dBm at 18 GHz
Phase noise: −110 dBc/Hz @ 1 GHz typical; −110 dBc/Hz @ 10 kHz offset at 1 GHz Display & Analysis
Up to 6 traces with 3 trace detectors and 12 markers
Measurements: channel power, occupied bandwidth, adjacent channel power ratio (ACPR), spectrum and spectrogram display Interfaces & Connectors
RF: W (m) connector
USB 3.0 with Type-C connector
External 10 MHz frequency reference input (REF, MCX(f), 50 Ω)
External TTL trigger input (TRIG, MCX(f), 50 Ω) Environmental
Operating temperature: 0 °C to 50 °C; storage: −40 °C to 71 °C
Maximum humidity: 95 % RH at 30 °C non-condensing
Shock, temperature, and humidity resistance per MIL-PRF-28800F Class 3
Explosive atmosphere rated to MIL-STD-810G Method 511.5, Procedure 1
Key Features
Ultraportable design enables direct connection to DUTs and field measurements
NLTL technology delivers >100 dB dynamic range without traditional mixer complexity
USB power operation removes dependency on external supplies
Windows-based control via PC, laptop, or tablet supports flexible deployment
Typical Applications
Microwave and millimeter-wave device development and production
Radio relay and satellite communication systems
Automotive radar and electronic warfare analysis
3G/4G/5G, 802.11ad/WiGig, and wireless backhaul commissioning
Radio astronomy and spectrum monitoring
Compatibility & Integration Control via Windows-based computing platforms; USB 3.0 connectivity supports laptop and tablet operation. External frequency reference and trigger inputs accommodate synchronized measurement scenarios.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 9 kHz to 90 GHz | Power Range (dBm): '+10 dBm to −136 dBm |
Anritsu MS2760A-0090 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Anritsu MS2760A-0090. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Anritsu MS2760A-0090 price
This Anritsu MS2760A-0090 is listed at $22,000. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Anritsu MS2760A-0090 calibration cost
NIST-traceable calibration for the Anritsu MS2760A-0090 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →