Anritsu MS9740A – Optical Spectrum Analyzer

Anritsu Optical Spectrum Analyzers. Dynamic Range: 58 dB at 0.4 nm from peak (standard), Accuracy: ±20 pm (1520–1620 nm, Bandwidth: 0.03.

Model
Anritsu MS9740A
Calibration
Available on request
Price
$7,500
Status
In stock
RFQ ref
MS9740A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Anritsu MS9740A Optical Spectrum Analyzer delivers precise spectral analysis across the visible to near-infrared band, addressing requirements in R&D and manufacturing environments. This instrument evaluates optical devices

SFP, XFP, and SFP+ modules, transceivers, VCSEL and DFB lasers - displaying center wavelength, level, spectrum, SMSR, and OSNR on a single screen. Fast measurement cycles under 0.2 seconds enable rapid device characterization.


When paired with a Bit Error Rate Tester, it supports comprehensive analysis of transceiver outputs and WDM signals.


Technical Specifications



  • Wavelength Range: 600 nm to 1750 nm

  • Dynamic Range: 58 dB at 0.4 nm from peak (standard); 60 dB at 0.4 nm (high mode); 70 dB at 1 nm from peak

  • Wavelength Accuracy: ±20 pm (1520–1620 nm, 0.03–0.2 nm resolution); ±50 pm (1530–1570 nm, 0.07–0.2 nm resolution); ±100 pm (1520–1620 nm, 0.5–1.0 nm resolution); ±300 pm (600–1520 nm)

  • Wavelength Linearity: ±20 pm (1520–1620 nm)

  • Resolution Bandwidth: 0.03, 0.05, 0.07, 0.1, 0.2, 0.5, 1.0 nm; minimum 30 pm

  • Level Accuracy: ±0.4 dB (1310/1550 nm, –10 dBm input, >0.1 nm resolution)

  • Level Linearity: ±0.05 dB (1550 nm, –30 to +20 dBm, optical ATT off)

  • Polarization Dependency: ±0.05 dB (1550/1600 nm)

  • Measurement Speed: <0.2 seconds (5 nm span)

  • Input Power Range: –90 to +10 dBm (1250–1600 nm); –85 to +10 dBm (1000–1250 nm, 1600–1650 nm); –65 to +10 dBm (600–1000 nm, 1650–1700 nm); –55 to +10 dBm (1700–1750 nm)


Key Features



  • Single-screen display of optical metrics

  • Dual dynamic range modes for flexibility in noise floor and signal separation

  • Fine resolution down to 30 pm for narrow-linewidth source characterization

  • High optical sensitivity to –90 dBm in critical C-band window


Typical Applications



  • Optical transceiver and module validation

  • Laser spectral purity and linewidth measurement

  • WDM signal analysis and channel isolation verification

  • OSNR and SMSR evaluation in optical systems


Compatibility & Integration Integrates with Bit Error Rate Testers for joint spectral and signal-quality assessment of optical transceivers.

Specifications

ParameterValue
Power Range (dBm)–90 to +10 dBm | Wavelength Range: 600 nm to 1750 nm

Frequently Asked Questions

What does the Anritsu MS9740A measure, and what is its wavelength range?
The MS9740A is a precision optical spectrum analyzer designed to measure optical power across a wavelength range of 600 nm to 1750 nm, covering visible through near-infrared bands. It delivers a dynamic range of 58 dB at 0.4 nm resolution (standard) with wavelength accuracy of ±20 pm in the 1520–1620 nm C-band region. The instrument's power measurement capability spans –90 to +10 dBm, making it suitable for characterizing WDM systems, ASE, and broadband optical sources in telecom and research applications.
What condition is this used MS9740A in, and what was verified before listing?
This unit is offered in used condition and has been power-tested to confirm basic operational status. We verify that the instrument powers on and responds to commands; however, we recommend obtaining a full calibration to validate measurement accuracy against your application requirements. Calibration services are available separately and documented through our service partners.
What does calibration cover for the MS9740A, and what is the cost and timeline?
Calibration for the MS9740A typically verifies wavelength accuracy, power linearity, and dynamic range performance against NIST-traceable standards. We offer calibration services starting at $450, which covers the standard measurement parameters for this model. Turnaround time and specific scope details are provided upon quote; contact our sales team for current lead times and service options.
What interfaces and connectivity options does the MS9740A support?
The MS9740A includes GPIB (IEEE-488) connectivity for remote instrument control and data acquisition, enabling integration into automated test systems and lab environments. The instrument is compatible with Anritsu's proprietary software and standard GPIB drivers available for Windows and Linux platforms. For detailed driver compatibility and software version information specific to your control system, we recommend consulting the original user manual or contacting Anritsu technical support directly.

Anritsu MS9740A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Anritsu MS9740A. Calibration covers wavelength accuracy at 850, 1310, 1550, and 1625 nm, power level accuracy, resolution bandwidth (RBW) accuracy, and dynamic range verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Anritsu MS9740A faults: wavelength motor failure, internal light source dimming, detector sensitivity loss. Common repairs include wavelength motor servicing, internal broadband source replacement, and detector recalibration after extended use.

Anritsu MS9740A price

This Anritsu MS9740A is listed at $7,500. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Anritsu MS9740A calibration cost

NIST-traceable calibration for the Anritsu MS9740A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers wavelength accuracy at 850, 1310, 1550, and 1625 nm, power level accuracy, resolution bandwidth (RBW) accuracy, and dynamic range verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents