Agilent/Keysight 71450B – Optical Spectrum Analyzer

Agilent / Keysight Optical Spectrum Analyzers. Power Range (dBm): -90 dBm to +30 dBm, Wavelength Range: 600 to 1700 nm.

Model
Agilent / Keysight 71450B
Calibration
Available on request
Price
$13,529
Status
In stock
RFQ ref
71450B
View cart

This unit

The Agilent/Keysight 71450B is a diffraction-grating-based optical spectrum analyzer for precise spectral characterization across 600 to 1700 nm. It measures optical power versus wavelength with sensitivity to -90 dBm and delivers 60 dB dynamic range, enabling detailed analysis of optical components, amplifiers, LEDs, DFB lasers, and Fabry-Perot lasers.


Technical Specifications

Wavelength Range: 600 to 1700 nm Sensitivity & Dynamic Range

  • Sensitivity: -90 dBm

  • Dynamic range: 60 dB

  • Maximum input power (monochromator): +30 dBm

  • Maximum photodetector input level: +20 dBm

  • Largest measurable power before compression: +10 dBm Wavelength Accuracy

  • Absolute accuracy: ±1 nm

  • After user calibration: ±0.3 nm

  • After calibration within ±0.05 nm of cal signal: ±0.2 nm

  • Span linearity (<40 nm spans): ±0.05 nm

  • Span linearity (1530–1570 nm): ±0.02 nm

  • Reproducibility (1 minute): ±0.005 nm

  • Reproducibility after calibration (1 minute): ±0.001 nm

  • Tuning repeatability: ±0.005 nm

  • Settability: ±0.005 nm Resolution Bandwidth

  • FWHM: <0.08 nm and 0.1 to 10 nm in 1,2,5 sequence

  • <0.08 nm setting: 0.065 nm ±15%

  • Resolution accuracy (≥0.5 nm, 1250–1600 nm): ±20%

  • Resolution accuracy (0.1–10 nm, 600–1700 nm): ±30%

  • Corrected bandwidth accuracy for noise markers (≥0.5 nm, 1250–1600 nm): ±3%

  • Corrected bandwidth accuracy (0.2 nm, 1250–1600 nm): ±5% Environmental

  • Operating temperature: 0° to 55° C

  • Relative humidity: <95%

  • Stabilization: 1 hour continuous operation plus auto-align routine Physical

  • Dimensions: 24 × 20 × 16 in

  • Weight: Approximately 35–50 lbs


Key Features



  • Unique double-pass monochromator architecture

  • Automatic spectral width measurement at -3 dB, -20 dB, or user-defined levels

  • Peak power determination and side-mode suppression ratio analysis

  • DFB stop-band characterization

  • Auto-align routine for sustained amplitude accuracy

  • Three instrument modes: preselector, stimulus response, and photodetector test


Typical Applications



  • Optical component characterization (couplers, switches, filters, fibers)

  • Laser source spectral analysis and quality assessment

  • LED spectral profiling

  • Stimulus-response measurements for optical devices


Compatibility & Integration Integrates the HP 70950B module for core measurement functionality. Accommodates HP 71451B photodetector for optimized performance across the operating wavelength range.

Specifications

ParameterValue
Power Range (dBm)'-95 dBm to 10 dBm | Wavelength Range: 600 nm to 1700 nm