JDS Uniphase MTA300

The JDS Uniphase MTA300 is a transceiver module designed for optical communication systems. It enables the transmission and reception of data over optical fiber, supporting high-speed data transfer rates. This transceiver is suitable for various applications, including telecommunications, data centers, and networking infrastructure.

Model
JDS Uniphase MTA300
Calibration
Available on request
Price
$3,200
Status
In stock
RFQ ref
MTA300
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The JDS Uniphase MTA300 is a programmable optical attenuator cassette designed for integration into the MTA Series Attenuator Shelf. It delivers precise, adjustable attenuation of optical signals across C-band and L-band wavelengths, making it essential for DWDM power equalization, transmission equipment testing, and optical system validation. The module operates as part of a modular, rack-mountable multi-channel system supporting up to eight cassettes in a single 19-inch chassis.

Technical Specifications

Attenuation Range: >60 dB programmable

Resolution: 0.5 dB

Accuracy: ±0.1 dB nominal

Wavelength Range: 1200 nm to 1700 nm (optimal: 1545 nm to 1645 nm)

Fiber Type: Singlemode (9/125 µm)

Connector Options: FC/PC, SC/APC

Power Supply: 100 V to 240 V AC, 50 Hz to 60 Hz

Power Consumption: 80 VA maximum

Fuse: (5×20) mm, T1A/250 V (slow-acting)

Key Features

Etalon-free optical design minimizes signal distortion

Low polarization dependent loss (PDL)

High return loss performance

Bidirectional optics - either fiber port functions as input

Integrated beam blocking switch for rapid attenuation to infinite loss, simulating fiber failure conditions

Retractable connector plate for maintenance and cleaning access

IEEE 488.2 (GPIB) remote control with SCPI command compatibility

LabVIEW drivers included for automated system control

Front panel keypad and display on controller cassette

Typical Applications

Power equalization in Dense Wavelength Division Multiplexing (DWDM) systems

Production testing and validation of optical transmission equipment

Optical communication system calibration and characterization

Compatibility & Integration The MTA300 operates within the MTA Series framework. Standard configurations pair the cassette with an MTA100 AC-powered chassis and MTA150 GPIB controller, accommodating up to eight attenuator modules in a single shelf. This modular architecture enables custom multi-channel configurations optimized for specific test requirements.

Specifications

ParameterValue
Voltage / Current Range100 V to 240 V AC, 50 Hz to 60 Hz, 80 VA max | Wavelength Range: 1200 nm to 1700 nm (optimal: 1545 nm to 1645 nm)

JDS Uniphase MTA300 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the JDS Uniphase MTA300. Calibration covers attenuation accuracy at 5 or more set values across the full range (0 to rated maximum dB), attenuation linearity, wavelength-dependent attenuation at 1310 nm, 1490 nm, and 1550 nm, insertion loss at minimum attenuation (0 dB position), and polarization-dependent loss (PDL) where applicable. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common JDS Uniphase MTA300 faults: motor and gear mechanism wear (attenuation steps or loss of smooth control), optical port contamination, EEPROM calibration data corruption. Most common faults are motor or gear mechanism wear on variable attenuators causing attenuation steps or loss of smooth control, optical port contamination reducing dynamic range, and EEPROM calibration data corruption on digitally controlled models.

JDS Uniphase MTA300 price

This JDS Uniphase MTA300 is listed at $3,200. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

JDS Uniphase MTA300 calibration cost

NIST-traceable calibration for the JDS Uniphase MTA300 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers attenuation accuracy at 5 or more set values across the full range (0 to rated maximum dB), attenuation linearity, wavelength-dependent attenuation at 1310 nm, 1490 nm, and 1550 nm, insertion loss at minimum attenuation (0 dB position), and polarization-dependent loss (PDL) where applicable. Turnaround is 1 to 3 business days after receipt. See full calibration details →