Anritsu MW920A Optical Time Domain Reflectometer with MH952A

Anritsu MW920A Optical Time Domain Reflectometer with MH952A,High-precision OTDR with MH952A module offering long-range testing and detailed event analysis. Suitable for telecom and CATV network installation, verification, and fault location with portability and field durability.

Model
Anritsu MW920A/MH952A
Calibration
Available on request
Price
$955
Status
In stock
RFQ ref
MW920A/MH952A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Anritsu MW920A Optical Time Domain Reflectometer paired with the MH952A module delivers high-precision fiber characterization for telecommunications and CATV network deployment. This field-portable OTDR system combines waveform trace and automated event analysis on a large LCD display, enabling rapid fault location and fiber verification. The instrument integrates automated optical connector status monitoring with visual alarm indication, supporting both installation qualification and in-service diagnostics across long-range fiber spans.


Technical Specifications

Measurement and Display

  • Simultaneous waveform trace and event table display on large LCD

  • Real-time waveform sweep update capability

  • Automated fault measurement and event detection

  • Automatic optical connector connection status check with alarm Data Handling

  • Optional built-in 3.5-inch FDD for measurement storage and retrieval


Key Features



  • High-precision OTDR for detailed optical event analysis

  • Field-ready portable design with durable construction

  • Visual LD Light Source option for visible fault location

  • Long-range testing capability across extended fiber plant


Typical Applications



  • Fiber optic network installation and acceptance testing

  • Cable fault location and diagnostics

  • Network verification and maintenance

  • Telecommunications infrastructure validation

  • CATV system deployment and troubleshooting


Compatibility & Integration The MW920A accepts the MH952A module and integrates with Anritsu's modular OTDR ecosystem, supporting expanded measurement capabilities and wavelength options through alternative modules.

Anritsu MW920A/MH952A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Anritsu MW920A/MH952A. Calibration covers distance accuracy verified against a calibrated fiber length reference, event loss measurement accuracy at splice and connector events, dead zone (event and attenuation) at rated pulse width, dynamic range verification at 1310 nm and 1550 nm, backscatter coefficient calibration, and return loss measurement accuracy. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Anritsu MW920A/MH952A faults: optical port connector damage or contamination, battery failure, display damage from field use, module failure on FTB or MTS platforms, calibration drift. Most field OTDRs fail due to physical damage. On modular platforms (EXFO FTB, Viavi MTS), individual module failures are serviced without replacing the entire mainframe. Optical port cleaning resolves many apparent measurement faults before mechanical repair is needed.

Anritsu MW920A/MH952A price

This Anritsu MW920A/MH952A is listed at $955. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Anritsu MW920A/MH952A calibration cost

NIST-traceable calibration for the Anritsu MW920A/MH952A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers distance accuracy verified against a calibrated fiber length reference, event loss measurement accuracy at splice and connector events, dead zone (event and attenuation) at rated pulse width, dynamic range verification at 1310 nm and 1550 nm, backscatter coefficient calibration, and return loss measurement accuracy. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents