Keysight (Agilent) N4690C Electronic Calibration Module (ECal), 300 kHz to 18 GHz, Type-N, 50 OHM, 2-Port

The Keysight N4690C is a 2-Port Electronic Calibration (ECal) module that simplifies vector network analyzer (VNA) calibration. Operating from 300 kHz to 18 GHz with Type-N connectors and a 50 Ohm impedance, it delivers fast, accurate, and consistent calibrations by automating the calibration process. ECal modules minimize manual operations, reducing errors and improving measurement repeatability. Ideal for various RF and microwave testing applications, the N4690C enhances productivity and ensures reliable performance of VNAs.

Model
Keysight / Agilent N4690C
Calibration
Available on request
Price
$4,200
Status
In stock
RFQ ref
N4690C
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Keysight (Agilent) N4690C is a 2-port electronic calibration module (ECal) that automates VNA calibration across 300 kHz to 18 GHz. Type-N connectors with 50 Ohm impedance enable full two-port calibration via single connection, eliminating manual mechanical kit procedures and reducing setup time. The module stores unique S-parameter data that computes error terms for the vector network analyzer, delivering NIST traceable accuracy.


Solid-state switching and USB control minimize operator error while improving measurement repeatability.


Technical Specifications



  • Frequency Range: 300 kHz to 18 GHz

  • Ports: 2-port configuration

  • Impedance: 50 Ohm

  • Connectors: Type-N (male/male, female/female, or male/female options available)

  • Control Interface: USB

  • Switching Technology: Solid-state

  • Accuracy: NIST traceable


Electrical Characteristics



  • Maximum Input Power: +9 dBm

  • Minimum Input Power: −45 dBm

  • Directivity: 43 dB to 50 dB (frequency dependent)

  • Source Match: 36 dB to 48 dB (frequency dependent)

  • Reflection Tracking: ±0.03 dB to ±0.15 dB (frequency dependent)

  • Transmission Tracking: ±0.05 dB to ±0.11 dB (frequency dependent)

  • Load Match: 36 dB to 42 dB (frequency dependent)


Key Features



  • Single-connection full two-port calibration eliminates multi-step mechanical procedures

  • Transfer standard design with embedded S-parameter data ensures consistent accuracy

  • Shorter female connector design enhances mechanical repeatability

  • Operating temperature: +20 °C to +26 °C

  • Environmental tolerance: Up to 95% relative humidity, non-condensing


Typical Applications



  • RF and microwave VNA calibration

  • Laboratory and field measurement verification

  • Production test environments requiring frequent recalibration


Compatibility & Integration Supported on Keysight PNA Series (N522X, N523X, N524X) and ENA Series vector network analyzers.

Specifications

ParameterValue
Frequency Range300 kHz to 18 GHz | Power Range (dBm): '-45 dBm to +9 dBm

Keysight / Agilent N4690C — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Keysight / Agilent N4690C. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Keysight / Agilent N4690C price

This Keysight / Agilent N4690C is listed at $4,200. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Keysight / Agilent N4690C calibration cost

NIST-traceable calibration for the Keysight / Agilent N4690C is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →