Exfo NR5000 Radiometer Module
Exfo Optical Power Meters. Accuracy: ±5% over 250–600 nm range, Power Range: 10 mW to 15 W, Resolution: 10 mW.
- Model
- Exfo NR5000
- Calibration
- Available on request
- Price
- $130
- Status
- In stock
- RFQ ref
- NR5000
This unit
The Exfo NR5000 Radiometer Module is a portable optical power measurement instrument for precise irradiance and power readings across the ultraviolet and visible spectrum. It integrates with EXFO optical test platforms to deliver high-accuracy measurements in laboratory and manufacturing environments. The module employs a proprietary flat-response detector and non-imaging optical interface to minimize measurement variation caused by source radiance and intensity fluctuations, while supporting multiple measurement modes and auto-sensing capabilities.
Technical Specifications
- Wavelength Range: 250 nm to 600 nm
- Accuracy: ±5% over 250–600 nm range
- Power Range: 10 mW to 15 W
- Resolution: 10 mW
- Operating Voltage: 9 V (battery)
- Detector System: Proprietary flat-response optical detector; uniform sensitivity across 250–600 nm
- Optical Interface: Non-imaging design; minimizes beam profile dependence
Key Features
- Measurement Modes: Power (Watts), irradiance (mW/cm² or W/cm²), real-time tracking, peak hold, relative (percentage of reference), and absolute (NIST-traceable) modes
- Light Guide Auto-Sensing: Detects 3 mm, 5 mm, and 8 mm industry-standard diameters automatically
- Smart Power Management: Auto-ON when optical signal ≥10 mW detected; auto-OFF after inactivity
- Auto-Ranging: Full-scale measurement range selected automatically
- Exchangeable Filters: Field-selectable wavelength ranges via EXFO filter cartridges (250–450 nm, 320–500 nm, 365 nm bandpass, 320–390 nm, 400–500 nm)
- Form Factor: Compact, hand-held design for portable operation
Interfaces and Compatibility
- Optical Input: Proprietary connector; compatible with EXFO light guide adapters
- Adapter Support: Works with Lamp Output Adapter and Proximity Measurement Adapter for flood geometry measurements
- Light Guide Coupling: Requires EXFO-compatible light guide adapters for 3 mm, 5 mm, and 8 mm guides
Specifications
| Parameter | Value |
|---|---|
| Voltage / Current Range | 9 V | Wavelength Range: 250 nm to 600 nm |
Exfo NR5000 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Exfo NR5000. Calibration covers detector responsivity at 850, 1310, 1490, 1550, and 1625 nm, absolute power accuracy, linearity across the full dynamic range, and reference power level. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Exfo NR5000 faults: detector contamination, damaged FC/PC input port, display failure. Common repairs include detector port cleaning or replacement, display repair, and battery or capacitor replacement in older HP/Agilent/Keysight units.
Exfo NR5000 price
This Exfo NR5000 is listed at $130. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Exfo NR5000 calibration cost
NIST-traceable calibration for the Exfo NR5000 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers detector responsivity at 850, 1310, 1490, 1550, and 1625 nm, absolute power accuracy, linearity across the full dynamic range, and reference power level. Turnaround is 1 to 3 business days after receipt. See full calibration details →