Johnson Controls P70AB-2 Single Pole Low Pressure Control

The Johnson Controls P70AB-2 is a single-pole, low-pressure control designed for use in refrigeration and air conditioning systems. It protects compressors from damage due to low suction pressure. The control automatically shuts down the compressor when the suction pressure drops below the setpoint and restarts it when the pressure rises above the cut-in point.

Model
Johnson Controls P70AB-2
Calibration
Available on request
Price
$125
Status
In stock
RFQ ref
P70AB-2
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Johnson Controls P70AB-2 is a single-pole, single-throw (SPST) low-pressure control for commercial refrigeration and air conditioning systems. This open-low switch functions as a low-pressure cut-out, pump-down control, and capacity control - automatically shutting down the system when suction pressure falls below setpoint and restarting when pressure rises above the cut-in point. The all-steel case delivers rugged protection in demanding environments while accommodating a broad pressure range of 20 in. Hg to 100 psig with differential adjustment from 6 psi to 50 psi (minimum 7 psi, maximum 50 psi). A 36-inch capillary tube with 1/4-inch flare nut connects to the pressure source, and sight-set calibrated adjustment provides field configuration. Maximum overpressure rating is 325 psig.

Technical Specifications

Pressure Range: 20 in. Hg to 100 psig

Differential Range: 6 psi to 50 psi (minimum 7 psi, maximum 50 psi)

Maximum Overpressure: 325 psig

Switch Type: Single Pole, Single Throw (SPST), Open Low

Pressure Connector: 36-inch capillary with 1/4-inch flare nut

Adjustment Method: Sight-set calibrated pressure adjustment; limited knob adjustment on select models

Construction: All-steel case and cover

Electrical Specifications

120 VAC: 18.7 A FLA, 120 A LRA; Pilot Duty 125 VA

208 VAC: 16.0 A FLA, 96.0 A LRA, 16.0 A non-inductive; Pilot Duty 125 VA

240 VAC: 9.2 A FLA, 55.2 A LRA, 9.2 A non-inductive; Pilot Duty 125 VA

208/240 VAC: 8.0 A FLA, 48.0 A LRA, 8.0 A non-inductive

Pilot Duty: 125 VA at 120–600 VAC; 57.5 VA at 120–300 VDC

Key Features

Compressor protection via automatic shutdown below setpoint

Sight-set calibration for precise field adjustment

Horizontal or vertical mounting on flat surfaces

36-inch capillary tube minimizes installation constraints

Typical Applications

Commercial refrigeration systems

Air conditioning systems

Pressure control for air, water, and oil applications

Compatibility & Integration

Compatible with R-12, R-22, R-134A, R-500, R-502, and other common non-corrosive refrigerants

Ammonia-compatible models available

Suitable for non-corrosive fluid applications

Specifications

ParameterValue
Voltage / Current Range120 VAC @ 18.7 A FLA

Johnson Controls P70AB-2 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Johnson Controls P70AB-2. Calibration covers I/O channel accuracy per specification, analog output and input calibration to rated accuracy, and functional communication interface test (serial, Ethernet, fieldbus). All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Johnson Controls P70AB-2 faults: blown I/O fuses, failed analog modules, power supply capacitor failure. Common faults include blown I/O protection fuses, failed analog I/O modules, power supply capacitor failure, and serial or Ethernet communication port damage.

Johnson Controls P70AB-2 price

This Johnson Controls P70AB-2 is listed at $125. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Johnson Controls P70AB-2 calibration cost

NIST-traceable calibration for the Johnson Controls P70AB-2 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers I/O channel accuracy per specification, analog output and input calibration to rated accuracy, and functional communication interface test (serial, Ethernet, fieldbus). Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents