u2t Photonics PPS-03 Photodetector Power Supply

II-VI / Finisar / u2t Photonics Optical Power Sensors.

Model
II-VI / Finisar / u2t Photonics PPS-03
Calibration
Available on request
Price
$850
Status
In stock
RFQ ref
PPS-03
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The II-VI / Finisar / u2t Photonics PPS-03 photodetector power supply is engineered to deliver consistent and precise power to photodetectors. This power supply is crucial for maintaining the integrity of optical signals and ensuring the accuracy of measurements in sensitive detection systems. It is suitable for use in telecommunications, research, and industrial environments where reliable photodetector operation is essential.

II-VI / Finisar / u2t Photonics PPS-03 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the II-VI / Finisar / u2t Photonics PPS-03. Calibration covers detector responsivity across all specified wavelengths (typically 800-1700 nm range), absolute power accuracy, and EEPROM calibration coefficient update. Compatible with Agilent/HP 8163A/B, 8164A/B, and 8166A/B mainframes.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common II-VI / Finisar / u2t Photonics PPS-03 faults: FC/PC connector damage, EEPROM failure (mainframe shows unrecognized sensor), reduced responsivity. Common faults include FC/PC input connector damage, EEPROM failure causing the module to appear unrecognized by the mainframe, and reduced detector responsivity from contamination.

II-VI / Finisar / u2t Photonics PPS-03 price

This II-VI / Finisar / u2t Photonics PPS-03 is listed at $850. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

II-VI / Finisar / u2t Photonics PPS-03 calibration cost

NIST-traceable calibration for the II-VI / Finisar / u2t Photonics PPS-03 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers detector responsivity across all specified wavelengths (typically 800-1700 nm range), absolute power accuracy, and EEPROM calibration coefficient update. Compatible with Agilent/HP 8163A/B, 8164A/B, and 8166A/B mainframes.. Turnaround is 1 to 3 business days after receipt. See full calibration details →