Advantest Q8344A 350nm-1750nm Optical Spectrum Analyzer

Advantest Optical Spectrum Analyzers. Resolution: 0.05 nm maximum (at 0.85 µm), Accuracy: ±0.1 nm (at 1.3 µm, Sensitivity: −70 dBm to +10 dBm (0.7 µm to 1.6 µm).

Model
Advantest Q8344A
Calibration
Available on request
Price
$14,179
Status
In stock
RFQ ref
Q8344A
View cart

This unit

The Advantest Q8344A is a benchtop optical spectrum analyzer spanning 350 nm to 1750 nm, engineered around Fourier spectrum analysis using a Michelson interferometer. This architecture enables direct optical coherence length measurements - a capability absent in monochromator-based instruments. The analyzer delivers wavelength resolution to 0.05 nm at 0.85 µm, wavelength accuracy of ±0.1 nm, and measurement speeds of approximately 1.5 seconds per sweep across any analysis span.


Dynamic range reaches 80 dB with input sensitivity from −70 dBm to +10 dBm across the 0.7 µm to 1.6 µm band. A built-in He-Ne laser reference ensures long-term measurement repeatability without external calibration.


Technical Specifications



  • Wavelength Range: 350 nm to 1750 nm

  • Measurement Principle: Fourier spectrum analysis; Michelson interferometer

  • Wavelength Resolution: 0.05 nm maximum (at 0.85 µm); 0.1 nm (at 1.31 µm)

  • Wavelength Accuracy: ±0.1 nm (at 1.3 µm, vacuum reference)

  • Measurement Speed: ~1.5 seconds per sweep

  • Span Range: 0.1 nm to 140 nm/DIV

  • Input Sensitivity: −70 dBm to +10 dBm (0.7 µm to 1.6 µm)

  • Level Accuracy: ±2.0 dB or less (at 0.85 µm and 1.31 µm)

  • Linearity: ±1.0 dB/25 dB or less; ±0.5 dB/10 dB or less

  • Dynamic Range: 80 dB

  • Reference: Built-in He-Ne laser


Key Features



  • Direct coherence length measurement capability via Michelson interferometer architecture

  • Fiber input: 50 µm standard; optional 200 µm available

  • Manual transportation lock on interferometer mechanism

  • GP-IB interface for instrument control

  • Optional built-in printer (Option 01)

  • Horizontal orientation required; 10 cm minimum clearance around air vents


Typical Applications



  • Laser diode characterization in optical data storage systems

  • Fiber optic gyroscope laser evaluation

  • LED and photoemitting element analysis

  • Telecommunications and data communications component testing

  • Optical device manufacturing quality assurance


Compatibility & Integration Benchtop form factor with GP-IB interface support. Operates in controlled environments free from thermal transients, mechanical shock, vibration, moisture, dust, and external magnetic fields.

Specifications

ParameterValue
Power Range (dBm)−70 dBm to +10 dBm | Wavelength Range: 350 nm to 1750 nm