Advantest Q8344A 350nm-1750nm Optical Spectrum Analyzer
Advantest Optical Spectrum Analyzers. Resolution: 0.05 nm maximum (at 0.85 µm), Accuracy: ±0.1 nm (at 1.3 µm, Sensitivity: −70 dBm to +10 dBm (0.7 µm to 1.6 µm).
- Model
- Advantest Q8344A
- Calibration
- Available on request
- Price
- $14,179
- Status
- In stock
- RFQ ref
- Q8344A
This unit
The Advantest Q8344A is a benchtop optical spectrum analyzer spanning 350 nm to 1750 nm, engineered around Fourier spectrum analysis using a Michelson interferometer. This architecture enables direct optical coherence length measurements - a capability absent in monochromator-based instruments. The analyzer delivers wavelength resolution to 0.05 nm at 0.85 µm, wavelength accuracy of ±0.1 nm, and measurement speeds of approximately 1.5 seconds per sweep across any analysis span.
Dynamic range reaches 80 dB with input sensitivity from −70 dBm to +10 dBm across the 0.7 µm to 1.6 µm band. A built-in He-Ne laser reference ensures long-term measurement repeatability without external calibration.
Technical Specifications
- Wavelength Range: 350 nm to 1750 nm
- Measurement Principle: Fourier spectrum analysis; Michelson interferometer
- Wavelength Resolution: 0.05 nm maximum (at 0.85 µm); 0.1 nm (at 1.31 µm)
- Wavelength Accuracy: ±0.1 nm (at 1.3 µm, vacuum reference)
- Measurement Speed: ~1.5 seconds per sweep
- Span Range: 0.1 nm to 140 nm/DIV
- Input Sensitivity: −70 dBm to +10 dBm (0.7 µm to 1.6 µm)
- Level Accuracy: ±2.0 dB or less (at 0.85 µm and 1.31 µm)
- Linearity: ±1.0 dB/25 dB or less; ±0.5 dB/10 dB or less
- Dynamic Range: 80 dB
- Reference: Built-in He-Ne laser
Key Features
- Direct coherence length measurement capability via Michelson interferometer architecture
- Fiber input: 50 µm standard; optional 200 µm available
- Manual transportation lock on interferometer mechanism
- GP-IB interface for instrument control
- Optional built-in printer (Option 01)
- Horizontal orientation required; 10 cm minimum clearance around air vents
Typical Applications
- Laser diode characterization in optical data storage systems
- Fiber optic gyroscope laser evaluation
- LED and photoemitting element analysis
- Telecommunications and data communications component testing
- Optical device manufacturing quality assurance
Compatibility & Integration Benchtop form factor with GP-IB interface support. Operates in controlled environments free from thermal transients, mechanical shock, vibration, moisture, dust, and external magnetic fields.
Specifications
| Parameter | Value |
|---|---|
| Power Range (dBm) | −70 dBm to +10 dBm | Wavelength Range: 350 nm to 1750 nm |
Frequently Asked Questions
- What does the Advantest Q8344A measure and what is its wavelength range?
- The Q8344A is a benchtop optical spectrum analyzer designed to measure optical power across a broad wavelength span from 350 nm to 1750 nm, covering UV through near-infrared regions. It delivers a maximum resolution of 0.05 nm at 0.85 µm and power measurement sensitivity ranging from −70 dBm to +10 dBm across the 0.7 µm to 1.6 µm band, making it suitable for telecom, fiber-optic component characterization, and broadband light source analysis. The instrument's wavelength accuracy of ±0.1 nm at 1.3 µm enables precise identification of spectral features and compliance verification in communications applications.
- What is the condition of this used Q8344A, and what verification was performed?
- This is a used unit offered as-is, meaning it has seen operational history but remains available for immediate deployment or laboratory service. We verify basic functionality and mechanical condition before listing; however, we recommend independent validation of performance parameters critical to your application, particularly sensitivity and wavelength calibration accuracy. Calibration services are available separately to restore the instrument to manufacturer specifications if needed.
- What does calibration cover for the Advantest Q8344A and what does it cost?
- Calibration for the Q8344A restores wavelength accuracy and power measurement traceability to NIST standards across the instrument's specified operating range. Our calibration service is available separately starting at $450 and typically includes full wavelength and power reference verification; contact us for current turnaround times and the complete scope of your specific calibration needs. This service is strongly recommended if the instrument's last calibration date is unknown or has exceeded your required interval.
- What interfaces and connectivity options does the Q8344A provide?
- The Q8344A supports GPIB (IEEE 488) control for remote operation and data acquisition in automated test systems, enabling seamless integration into rack-and-stack laboratory setups. Driver and command-set documentation are typically available through Advantest; we recommend verifying driver compatibility with your operating system and control software prior to purchase. Standard RS-232 serial connectivity is also present for configuration and basic instrument communication in legacy system integrations.
Advantest Q8344A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Advantest Q8344A. Calibration covers wavelength accuracy at 850, 1310, 1550, and 1625 nm, power level accuracy, resolution bandwidth (RBW) accuracy, and dynamic range verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Advantest Q8344A faults: wavelength motor failure, internal light source dimming, detector sensitivity loss. Common repairs include wavelength motor servicing, internal broadband source replacement, and detector recalibration after extended use.
Advantest Q8344A price
This Advantest Q8344A is listed at $14,179. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Advantest Q8344A calibration cost
NIST-traceable calibration for the Advantest Q8344A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers wavelength accuracy at 850, 1310, 1550, and 1625 nm, power level accuracy, resolution bandwidth (RBW) accuracy, and dynamic range verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →