Advantest R3768/R3770 – Network analyzer

Advantest Network Analyzers. Frequency Range: R3768: 300 kHz to 8 GHz; R3770: 300 kHz to 20 GHz, Power Range (dBm): –9 to +11 dBm (300 kHz–0.5 GHz); –7 to +13 dBm (0.5–4.0 GHz); –10 to +10 dBm (4.0–6.0 GHz); –12 to +8 dBm (6.0–8.0 GHz); Extended: –74 to +6 dBm (300 kHz–0.5 GHz); –72 to +8 dBm (0.5–4.0 GHz).

Model
Advantest R3768/R3770
Calibration
Available on request
Price
$5,397
Status
In stock
RFQ ref
R3768/R3770
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Advantest R3768/R3770 network analyzer series delivers precision S-parameter measurement across extended frequency ranges, serving R&D, manufacturing, and quality control environments. The R3768 operates from 300 kHz to 8 GHz, while the R3770 extends to 20 GHz, both with 1 Hz setup resolution. These instruments characterize 2-, 3-, and 4-port networks with full S-parameter acquisition and flexible measurement formats including rectangular, Smith Chart, polar coordinates, and impedance/admittance conversion.


Dynamic range reaches 125 dB typical, with trace noise as low as 0.0025 dBrms at low frequencies and sweep speeds of 5 µs/point. Temperature stability holds 0.01 dB/°C to 2.6 GHz, degrading to 0.03 dB/°C above 8 GHz. Frequency accuracy is ±10 ppm at 23 ±5°C, with ±15 ppm stability across 5–40°C operation and ±3 ppm/year drift.


The integrated software fixture function enables real-time virtual matching circuit simulation, standardized impedance transformation, and software balun analysis for balanced component evaluation.


Technical Specifications



  • Frequency Range: R3768: 300 kHz–8 GHz; R3770: 300 kHz–20 GHz

  • Frequency Resolution: 1 Hz

  • S-Parameter Measurement: 2-port (S11, S21, S12, S22); 3-port (9 parameters); 4-port (16 parameters)

  • Measurement Formats: Rectangular (amplitude linear/log, phase, group-delay, VSWR, complex); Smith Chart; R+jX, G+jB; Polar (linear/log amplitude, phase, complex)

  • Dynamic Range: Up to 125 dB typical

  • Trace Noise: 0.0025 dBrms (300 kHz–10 MHz); 0.005–0.080 dBrms above 10 MHz depending on frequency

  • Output Power Range (8 GHz 2-port): –9 to +11 dBm (300 kHz–0.5 GHz); –7 to +13 dBm (0.5–4.0 GHz); –10 to +10 dBm (4.0–6.0 GHz); –12 to +8 dBm (6.0–8.0 GHz)

  • Extended Power Output: –74 to +6 dBm (300 kHz–0.5 GHz); –72 to +8 dBm (0.5–4.0 GHz)

  • Frequency Accuracy: ±10 ppm (23 ±5°C); ±15 ppm (5–40°C); ±3 ppm/year

  • Temperature Coefficient: 0.01 dB/°C (300 kHz–2.6 GHz); 0.02 dB/°C (2.6–8.0 GHz); 0.03 dB/°C (8.0–20 GHz)

  • Sweep Speed: 5 µs/point minimum


Key Features



  • Multi-port measurement capability with impedance/admittance conversion

  • Software fixture function for virtual matching circuit simulation

  • Software balun simulation for balanced parameter analysis

  • Selectable rectangular, Smith Chart, and polar coordinate display modes


Typical Applications



  • Component characterization (filters, amplifiers, antennas, transmission lines)

  • Circuit design validation and tuning

  • Manufacturing test and incoming inspection

  • Quality assurance across production batches

Specifications

ParameterValue
Frequency RangeR3768: 300 kHz to 8 GHz
R3770300 kHz to 20 GHz | Power Range (dBm): –9 to +11 dBm (300 kHz–0.5 GHz)
Extended–74 to +6 dBm (300 kHz–0.5 GHz)

Advantest R3768/R3770 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Advantest R3768/R3770. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Advantest R3768/R3770 price

This Advantest R3768/R3770 is listed at $5,397. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Advantest R3768/R3770 calibration cost

NIST-traceable calibration for the Advantest R3768/R3770 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →