Anritsu S810C – Site Master Microwave Transmission Line and Antenna Analyzer; 3.3 GHz to 10.5 GHz
Anritsu S810C – Site Master Microwave Transmission Line and Antenna Analyzer; 3.3 – 10.5 GHz,A reliable field-grade site master analyzer covering 3.3–10.5 GHz. Enables accurate fault detection and transmission diagnostics on microwave transmission lines and antennas. Ideal for telecom contractors and infrastructure testing.
- Model
- Anritsu S810C
- Calibration
- Available on request
- Price
- $2,800
- Status
- In stock
- RFQ ref
- S810C
This unit
The Anritsu S810C Site Master is a handheld, battery-operated microwave transmission line and antenna analyzer covering 3.3 GHz to 10.5 GHz. Purpose-built for installation, verification, troubleshooting, and repair of microwave communication systems, it delivers accurate fault detection and transmission diagnostics across coaxial cables and waveguides. The instrument combines vector error correction and waveguide dispersion compensation to enhance measurement accuracy and repeatability. Superior RF interference immunity to -10 dBm - including on-channel interference - ensures reliable operation in live network environments. Distance-to-Fault analysis with up to 517 selectable data points enables long-range fault localization. Non-volatile memory stores 200 measurement traces for field documentation and trend analysis.
Technical Specifications
Frequency Range: 3.3 GHz to 10.5 GHz
Display Resolution: 130, 259, or 517 selectable data points
Frequency Accuracy (CW mode): ±75 ppm @ +25°C
RF Interference Immunity: -10 dBm
Test Port Connector: K(f) for standard models; N(f) for specific variants
Weight: 1.89 kg (4.2 lbs) including battery
Dimensions: 25.4 × 17.8 × 6.10 cm (10 × 7 × 2.4 in)
Operating Temperature: 0 to 50°C
Storage Temperature: -20°C to 75°C
Measurement Trace Memory: 200 traces (non-volatile)
Key Features
Return Loss measurement for reflected power detection
SWR analysis for impedance mismatch quantification
Cable Loss measurement for attenuation characterization
Distance-to-Fault (DTF) localization with up to 517 data points
Tune Mode for fast waveguide component adjustment
Vector Error Correction for improved measurement repeatability
Waveguide Dispersion Correction for frequency-dependent propagation velocity
RS232 interface (9-pin D-sub) with configurable baud rates: 9600, 19,200, 38,400, 56,000, or 115,200 bps
Typical Applications
Microwave transmission line installation and commissioning
In-service antenna system verification
Coaxial and waveguide fault diagnosis
Field troubleshooting of microwave communication links
Waveguide flange connector optimization
Compatibility & Integration Optional AC/DC adapter (40-115) and 12 Volt DC cigarette lighter adapter (806-62) support fixed-site operation. Rechargeable NiMH battery (633-27) and external charger (2000-1029) available. Meets CE electromagnetic compatibility requirements. RS232 connectivity enables integration with external data logging and analysis systems.
Anritsu S810C — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Anritsu S810C. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Anritsu S810C price
This Anritsu S810C is listed at $2,800. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Anritsu S810C calibration cost
NIST-traceable calibration for the Anritsu S810C is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →