Agilent/Keysight SL1002A High Voltage DAQ Module

The Agilent/Keysight SL1002A is a standalone logic analyzer with a focus on high-speed digital design and debug. It features deep memory, advanced triggering, and state/timing analysis capabilities, and is ideal for verifying, debugging, and optimizing digital systems.

Model
Agilent / Keysight SL1002A
Calibration
Available on request
Price
$2,100
Status
In stock
RFQ ref
SL1002A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Agilent/Keysight SL1002A is a solid battery test system designed for cell-level analysis, providing sink and source capabilities for automotive and industrial applications. This system is engineered to deliver reliable, precise, and reproducible measurement results, focusing on characterizing various aspects of battery cells.

Technical Specifications General Capabilities:

  • Product Type: Battery Test System – Cell Level
  • Application Focus: Characterization of battery cells, including internal resistance, mechanical resistance, efficiency, capacity, cyclical life, and calendar life spans.
  • System Architecture: Standalone unit with a Measurement and Control Unit (MCU) running on a real-time Linux PC.
  • Efficiency: Greater than 90% efficiency, with a bidirectional power supply that returns energy to the power mains.
  • Configuration: Modular design allowing adaptation of the number of channels to changing requirements.
  • Environmental Operation: * Ambient Temperature: 10 to 40 °C * Air Humidity: 30 to 75% relative humidity * Sound Pressure Level: < 70 dB(A) measured at 1 meter distance from the front, according to DIN EN 3744.
  • Protection Rating: IP 54 Electrical Characteristics:
  • Voltage Range: 0 to 6 V
  • Output Current Options: ±100 A, ±300 A, ±600 A per channel.
  • Power Class per Channel: 0.6 kW, 1.8 kW, 3.6 kW
  • Measurement Accuracy: * Overall system accuracy: 0.05% * Voltage measurement: Four-wire measurement. * Current measurement: Offset accuracy is multiplied by two when connecting two channels in parallel.
  • Sample Rate (Data Acquisition): Maximum of 20 kS/s internally (625 kS/s).
  • Temperature Input: Up to three temperature inputs per channel (Pt100, 4-wire), with a range of -50 to +130 °C and an accuracy of ±1 K per test channel. Functional Capabilities:
  • Sink and Source Emulation: Emulates sink and source for battery cells.
  • Autonomous Sequence Control: Enables independent control of test sequences.
  • Data Acquisition: Captures and stores measurement data.
  • Safety Features: * Inherent safety against overheating, overcapacity, short circuit, and idling. * Protection against reverse polarity is verified before output contactors close. (Note: No hardware protection against reverse polarity is present). * Monitoring of all internal voltages, currents, and temperatures. * DC output contactors capable of disconnecting the DUT at full load current.
  • Electrochemical Impedance Spectroscopy (EIS): Optional integrated EIS measurement capability without changing the DUT contact. Connectivity and Interfaces:
  • Communication Interface: Ethernet.
  • Control of External Components: Capable of controlling external components such as temperature chambers and conditioning units via Ethernet protocol. Physical Characteristics:
  • Dimensions and Weight: Specific dimensions and weight vary depending on the configuration. The system can be placed on a 15 cm high base stand or high rollers for flexible mobility. Software and Control:
  • Primary Control Software: Scienlab Energy Storage Discover (ESD) for individual test system control and monitoring.
  • Laboratory Management Software: PathWave Lab Operations for Battery Test for managing and coordinating entire battery testing laboratories with multiple systems.
  • Operating System: Windows 10 support for the control software. Scalability and Configuration Options:
  • Channel Flexibility: Perform the same or different tests on each channel.
  • Manual Parallel Operation: Up to six output stages can be manually paralleled. The output contacts and sense circuit require customer interconnection.
  • Automated Parallel Connection: Option SL1079A-CM2 for automated parallel connection of two channels, including monitoring of current and voltage limits.
  • Director/Follower Definition: Configurable via the ESD software.

Compatibility * Software Integration: Compatible with Keysight Scienlab Energy Storage Discover (ESD) software and PathWave Lab Operations for Battery Test.

  • External Component Control: Supports integration with external components like temperature chambers and conditioning units via Ethernet.

Included Accessories and Options * SL1079A-CM2: Automated parallel connection of two channels. Why Choose Aumictech for Keysight SL1002A?

At Aumictech, we specialize in supplying high-end battery testing equipment. Whether you need precise cell characterization, reliable performance verification, or scalable test solutions, our team ensures the Keysight SL1002A delivers maximum performance for your application.

Agilent / Keysight SL1002A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight SL1002A. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Agilent / Keysight SL1002A price

This Agilent / Keysight SL1002A is listed at $2,100. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Agilent / Keysight SL1002A calibration cost

NIST-traceable calibration for the Agilent / Keysight SL1002A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents